OSHA air sample results chain of custody, 55 Church Street

Machine-extracted title · confidence 85%

Chain of custody documentation for OSHA-compliant air sampling and abatement verification at the hotel located at 55 Church Street.

NYC-WTC_000103467–000103603
Page image
Scanned page image, NYC-WTC_000103488
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWEL. ':_ABORATORIES, INC. Environmental Laboratory NYsELAP%11142 47 Hudson Street, Ossining, New York 10562 NvuAP#2000a3-o AIHA # 100147

r-PCM AIR SAMPLE RESULTS • Client: Bovis Lend Lease Date Collected: 02/20/02 Date Rec'd (lab): 02/21/02 Project #: MBO-025AB Analysis Date: 02/21/02 Analyst: J. Yarusso Sample Location: The Millenium Hilton 55 Chruch Street Analytical Method: NIOSH 7400 • New York, New York

Field Technician: K. LaverenkolS. Manukov

Sample #:

06Pers Sample Location:

_ Victor Soto Sample Work Type [ Location

Personal Lobby - 02PCM — #E Volume Duration Concentration (min.) f/cc

3225 75 30 0.0360 PH STEL 20th Floor Victor Soto_ _ _ Person Aal 2Lobb 08Pers ._----- ---- PII - y 3227 300 120 0.0204 TW 0th Floor Personal Lobby - 14Pers P11 TWA 20th Floor 3233 456 190 0.0091

19 Blank Blank N/A 3238 0 0 N/A

20 Blank Blank N/A 3239 0 0 N/A

Total Duration Sampled (min.) 340 Short Term Exposure Limit (STEL) 0.0361 8 hr. Time Weighted Average (TWA) 0.011

(c) Permissible exposure limits (PELS)

(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or by an equivalent method.

(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or by an equivalent method.

Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.

• Limit of quantitation based on volume of air collected and 5.51/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the -limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. "' Laboratory QC data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be S reproduced except in full, without the written approval of Testwell Laboratories, Inc.

A'

Deborah McCarl - Laboratory Director

0

NYC-WTC 000103488

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103488Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →