NYC 9/11 Public Portal Document
I
L
-I(
TESTWEL -LABORATORIES, INC.
Environmental Laboratory i vs aAP # 11142
47 Hudson Street, Ossining, New York 10562 WLAP#200083-0
AJHA# 100147
r-PCM AIR SAMPLE RESULTS
•
Client: Bovis Lend Lease Date Collected: 02/20/02
Date Rec'd (lab): 02/21/02
Project #: MBO-025AB Analysis Date: 02/21/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample Work Duration Concentration
Sample #: Sample Location: 2PCM #
Type Location Volume (min.) f/cc
Michael Carlson Personal Lobby -
05Pers -- -----------Pn 3224 75 30 0.0392
STEL 20th Floor
Michael Ca_ rlson Personal Lobby -
07Pers -- ------------ 3226 300 120 0.0229
pll
TWA 20th Floor
Michael_ Carlson._._._,_ Personal Lobby -
13Pers 3232 456 190 0.0140
PII TWA 20th Floor
19 Blank Blank N/A 3238 0 0 N/A
20 Blank Blank N/A 3239 0 0 N/A
Total Duration Sampled (min.) 340
Short Term Exposure Limit (STEL) 0.039:
8 hr. Time Weighted Average (TWA) 0.0131
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
itimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
an equivalent method.
with HEPA
J Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. '•" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCartt -- Laboratory Director
NYC-WTC 000103486
OCR can misread numbers and units. Confirm readings against the page image before using them.