NYC 9/11 Public Portal Document
LL
TESTWELI LABORATORIES, INC.
Environmental _..boratory Nv3ELAP511142
•
47 Hudson Street, Ossining, New York 10562 NvL. a 200083-o
AIHA a 100147
PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/20/02
• Date Rec'd (lab): 02/21/02
Project #: MBO-025AB Analysis Date: 02/21/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Location:
Sample I Work Duration Concentration
02PCM # Volume
Type Location (min.) f/cc
Sachowski, David Personal Entire
02Pers - ---------- ------------ 3221 75 30 0.0654
STEL Building
Sachowski, David Personal Entire
04Pers - ----------- --- 3223 300 120 0.0139
I._.-.-.-.-.-.-.P!!._.-...-.-.-.... TWA Building
Sachowski. David_._._. Personal Entire
12Pers _ pil 3231 432 180 0.0380
TWA Building
Sachowski David Personal Entire
17Pers '------------- 3236 352 160 0.0390
PII TWA Building
19 Blank Blank N/A 3238 0 0 N/A
20 Blank Blank N/A 3239 0 0 N/A
Total Duration Sampled (min.) 490
Short Term Exposure Limit (STEL) 0.065s
8 hr. Time Weighted Average (TWA) 0.034E
(c) Permissible exposure limits (PELS)
(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
itimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
an equivalent method.
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
with HEPA
' Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the-limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "* Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (t'1VLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testweil Laboratories, Inc.
Deborah McCall - Laboratory Director
NYC-WTC 000103484