NYC 9/11 Public Portal Document
• TESTWELL LABORATORIES, INC.
Environmental Laboratory ?rrs EL.P x 11142
47 Hudson Street, Ossining, New York 10562 MILAP # 2orl a3-0
100147
PCM AIR SAMPLE RESULTS
0
Client: Bovis Lend Lease Date Collected: 02/12/02
Date Rec'd (lab): 02/13/02
Project #: MBO-025AB Analysis Date: 02/13/02
Analyst: D. Agarest
Sample Location: The Millenium Hilton
• 55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Location: 1 Sample
Type
.Work
Location
02PCM # Volume
Duration Concentration
(min.) f/cc
Michael Carlson Personal Entire
11Pers 2611 75 30 0.0523
P. _ _ _i STEL Building
Michael._ar(;;Qn._. Personal Entire
12Pers 2612 552 240 0.0148
Building
20 Blank Blank N/A 2620 0 0 N/A
21 Blank Blank N/A 2621 0 0 N/A
Total Duration Sampled (min.) 270
Short Term Exposure Limit (STEL) 0.052:
8 hr. Time Weighted Average (TWA) 0.010'
Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, cr
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, cr
by an equivalent method.
Protection: Half face negative air resoirator equip with HEPA
Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
•
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product -endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCarl - Laboratory Director
S.
'A
________________
____________
NYC-WTC 000103592
OCR can misread numbers and units. Confirm readings against the page image before using them.