NYC 9/11 Public Portal Document
• L TESTWEL_ LABORATORIES, INC.
Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
NYSELAP#11142
NVLAP x 2000aa-o
AIHA # 100147
E--PCM AIR SAMPLE RESULTS
• Client: Bovis Lend Lease Date Collected: 02/12/02
Date Rec'd (lab): 02/13/02
Project #: MBO-025AB Analysis Date: 02/13/02
Analyst: D. Agarest
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
• New York, New York
Field Technician: K. Laverenko/S. Manukov
Duration Concentration
Sample #: Sample Location: Sample Work 02PCM # Volume
Type Location (min.) f/cc
Sachowski, David Personal Entire
OlPers 2601 75 30 0.1471
STEL Building
Sachowski, David Personal Entire
02Pers ------------ -- ------------- 2602 300 120 0.0202
PII TWA Building
Sachowsk; David Personal Entire
19Pers ; 2619 276 120 0.0155
Pil l TWA Building
20 Blank Blank N/A 2620 0 0 N/A
21 Blank Blank N/A 2621 0 0 N/A
Total Duration Sampled (min.) 270
Short Term Exposure Limit (STEL) 0.1471
8 hr. Time Weighted Average (TWA) 0.0181
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, cr
by an equivalent method.
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes. as determined by the method prescribed in Appendix A to this section, cr
by an equivalent method.
1RespiratorY Protection: Half face negative air respirator squiD with HEPA cartridge.
Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "'* The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCai - Laboratory Director
-
a
-te
--
NYC-WTC 000103577
OCR can misread numbers and units. Confirm readings against the page image before using them.