OSHA air sample results chain of custody, 55 Church Street

Machine-extracted title · confidence 85%

Chain of custody documentation for OSHA-compliant air sampling and abatement verification at the hotel located at 55 Church Street.

NYC-WTC_000103467–000103603
Page image
Scanned page image, NYC-WTC_000103567
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. 1 L Environmental Laboratory trtreet, Ossining, New York 10562 47 HudsonS t,YS EL;P a 11142 nVaPa2CC083-o A HA W0147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 02/13/02 Date Rec'd (lab): 02/14/02 Project #: MBO-025AB Analysis Date: 214/02 • Analyst: D. Agarest Sample Location: The Millenium Hilton 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York

Field Technician: K. Laverenko/S. Manukov

Sample #: Sample Location: I Sample Work 02PCM # Volume Duration Concentration Type Location (min.) f/cc

11Pers -Danny McTough PII I Personal TWA 1 Scaffold Entire 2719 432 180 0.0649 1 20 Blank Blank N/A 2728 0 0 N/A

21 Blank Blank N/A 2729 0 0 N/A

Total Duration Sampled (min.) 180 8 hr. Time Weighted Averace (TWA) 0.02431

Permissible exposure limits (PELS)

C1 (c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or by an equivalent method.

(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or by an equivalent method.

Protection: Half face negative air resoirator equio with HEPA cartridge.

Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. "' Laboratory QC data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Deborah McCall - Laboratory Director

NYC-WTC 000103567

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103567Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →