NYC 9/11 Public Portal Document
TESTWELL LABORATORIES, INC.
•
IL Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
r_ PCM AIR SAMPLE RESULTS
NYS FLAP
NVLAP a
a
11142
200083-0
AIHA t 100147
a
Client: Bovis Lend Lease Date Collected: 05/28/02
Date Rec'd (lab): 05/29/02
Project #: MBO-025AB Analysis Date: 05/29/02
Analyst: A. Sokol
Sample Location Millenium Hilton @ WTC
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Various Floors Sample Condition Acceptable? YES
Field Technician T. Chhetry
Sample #: Sample Location:
Sample
Type
02PCM Volume
Concentration
f/cc
I
Outside Work Area Clean Room of During 14578 1200 0.0025
325
•
Remote Personal Decon
M •
326
327
Outside Work Area Remote Waste
Decon
Outside Work Area 46th Floor Inside
During
During-
14579
14580
1200
1200
<0.0023
<0.0023
Airlock
Outside Work Area 46th
328 Floor During 14581 1200 0.0025
Freight Elevator Lobby
Outside Work Area 45th Floor Inside During 14582 1200
I 329
Airlock
<0.0023
I 330
Outside Work Area 45th Floor
Freight Elevator Lobby
During 14583 1200 <0.0023
Outside Work Area 44th Floor Inside
331 During. 14584 1200 <0.0023
Airlock
Outside Work Area 44th
332 Floor During 14585 1200 <0.0023
-Freight Elevator Lobby
Outside Work Area 43rd Floor Inside During 14586 1350 <0.0018
333
Airlock
Outside Work Area 43rd Floor
334 During 14587 1350 0.0024
Freight Elevator Lobby
Outside Work Area 42nd Floor Inside
335 During 14588 1350 0.0020
Airlock
Outside Work Area 42nd Floor During 14589 1350 0.0025
336
Freight Elevator Lobby
Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report
value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at
P(0.05) Indicating the 95% confidence level at 2 standard deviations. " Sample information is provided by the client &
• presented as stated. '"' Laboratory QC data available upon request '"" The laboratory has no control over air
• sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be
used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or
any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full,
without the written approval of Testwell Laboratories, Inc.
• Deborah McCarf - Laboratory Director
Page 1 of 1 • -.
NYC-WTC 000103267
OCR can misread numbers and units. Confirm readings against the page image before using them.