NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 36/No folder label
Document / 262 pages

PCM air sample results chain of custody, 200 Park Avenue

Machine-extracted title · confidence 85%

Chain of custody forms for personal protective equipment and air sampling results conducted at 200 Park Avenue by Testwell Laboratories.

NYC-WTC_000103205–000103466
Page image
Scanned page image, NYC-WTC_000103259
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

• 9'llb TESTWELL LABORATORIES, INC. Environmental Laboratory NYS EIA➢ 0 11142

47 Hudson Street, Ossining, New York 10562 NVLAP a

20008:3.0 AM S 100147

• PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/23/02 Date Rec'd (lab): 05/24/02 Project #: MBO-025AB Analysis Date: 05/24/02 Analyst: D. McCarl Sample Location Millenium Hilton @ WIC 55 Chruch Street Analytical Method: NIOSH 7400 •

New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

tion: Sample Volume Concentration Sample #: Sample Loca r02PCM Type f/cc

Outside Work Area 47th Floor Inside During 14259 1300 0.0030 291 Airlock Outside Work Area 47th 292 Floor During 14260 1300 0.0040 Freight Elevator Lobby •

Outside Work Area 46th Floor Inside 293 During 14261 1300 0.0041 Airlock Outside Work Area 46th Floor During 14262 1300 0.0036 294 Freight Elevator Lobby Outside Work Area 45th Floor Inside During 14263 1300 <0.0021 295 Airlock Outside Work Area 45th 296 Floor During 14264 1300 0.0028 Freight Elevator Lobby Outside Work Area 6th Floor MER During 14265 1300 0.0075 297 Inside Airlock Outside Work Area 6th Floor MER During 14266 1300 0.0091 298 • Freight Elevator Lobby

299 Field Blank Blank 14267 0 N/A

300 Field Blank Blank 14268 0 N/A

L7 301 Field Blank Blank 14269 0 N/A

302 Field Blank Blank 14270 0 N/A

Limit of quantitation based on volume of air collected and 5.5 (1100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) Indicating the 95% confidence level at 2 standard deviations. " Sample information is provided by the client & • presented as stated. "' Laboratory QC data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Deborah McCall - Laboratory Director

Page 1 of 1

NYC-WTC 000103259

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103259Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →