NYC 9/11 Public Portal Document
Al L A33L)L-TAIL , JIiNL
104 E 25th Street, 10th Floor
I New York,NY10010
TeL 212-353-8280
Ii Fax 212-353-8306
I
REPORT DATE: 08-02-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
2nd Floor, 5th Floor (Rm 501A, 501)
PROJECT NUMBER: M477-15217129881
SAMPLED BY: Client
SAMPLE DATE 08-01-02
DATE RECEIVED: 08-02-02
DATE ANALYZED: 08-02-02
SAMPLE MEDIA; Air Samples
ANALYSIS REQUIRED: Method NTOSH 7082
ANALYSTS RE
SAMPLE BATCH SAMPLE DESCP-MTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(µgfrn') (ug/mt)
L-01 20856 Antonio Cuzco SS# 078-67-8976 <3.3 3.3
L-02 20856 Cesar Chalen SS# 090-52-2168 <3.3 3.3
L.03 20856 Eloy Cuzco SS# 078-67-3976 <5.6 5.6
L-04 20856 Antonio Cuzco SS# 078-67-8976 <3.6 3.6
L-05 20856 Cear Chole SSTM 090=52-2168 <3.6 3.6
L-06 20856 Eloy Cuzco SS# 078-67-8976 <3.8 3.8
L-07 20856 Field Blank <1.5 µs 1.5 gg
L-08 20856 Field Blank <1.5 µg 1.5 µg
NOTE 1:
THE REPORTING LIMIT (RL) IS 3.0 µg
NOTE 2: OSHA has
At the pros it time there as no regulatory levels or roquirtanmts for indoor airborne lead in area samples. However,
ctablished an action level of 30 .zg/mt and a permisible cxposum level (PEL) of 5C µg/mt for personal samples.
NOTE 3:
Blank traits are in Frg
NYC-WTC 000103006