3. Sample collection methodologies shall be in accordance with Title 15, Chapter 1 of the Rules of the
City of New York (RCNY) and AHERA regarding documentation and sample locations and the
requirements set forth herein regarding the rates of flow, and required volumes to achieve the
necessary analytical sensitivity.
4. Sampling equipment shall be placed at representative locations and away from obstruction.
Sampling cassette must be placed on a tripod and not taped to existing surfaces. All air sampling
equipment shall be pre- and post- calibrated to insure accurate air sampling volumes.
5. The Air Sampling Technician shall perform clearance air sampling after the areas are free of dust
accumulations as determined by the Project Monitor. All surfaces must be completely dry prior to
the start of sampling. Clearance air sampling shall be performed at each apartment, commercial
space, and the basement. Five samples shall be collected in each apartment, commercial space, and
basement and two samples shall be collected at the first floor lobby. The elevator shaft shall be
cleared separately. Clearance air monitoring shall be performed after the completion of all clean up
activities at the work site. Clearance air sampling shall be aggressive and performed in accordance
with Title 15, Chapter 1 of the RCNY Section 1-43 (a)-(d).
6. Clearance air samples shall be collected in accordance with the procedures specified in the NIOSH
7400 Method. The flow rate for collection of air samples shall be at least 10 liters per minute and no
more than 15 liters per minute. Air sampling cassettes must be monitored to ensure the filters do not
develop dark spots that would indicate clogging. The minimum sampling volume is 3600 liters. If
clogging develops, the cassette must be changed.
7. All clearance air samples and completed chain of custody forms must be transported to the
laboratory immediately after sampling is completed.
Clearance Criteria
1. The following clearance levels have been established by the USEPA for clean up activities resulting
from the collapse of the WTC.
Table 2: Clearance Criteria
Parameter Clearance Level Note
Asbestos in air 0.0009 f/cc PCMe Primary clearance level
Lead in settled dust <25 Primary clearance level
Dioxin in settled dust <4ng/m2 Primary clearance level
Fibrous glass in air <0.01 f/cc Secondary clearance level
Crystalline silica in air 1 m3 Secondary clearance level
PAHs in settled dust mg/rn2
<0.3 mg/m2 Primary clearance level
2. Cleaning shall not be considered complete unless the primary clearance levels are achieved (see
Table 2). The apartment will be re-cleaned and retested if the primary clearance levels are not
achieved. These clearance levels may be re-evaluated and revised if determined necessary based on
field conditions and analytical limitations. Secondary clearance levels shall be considered in
determining the need for additional cleanup, however failure to meet the secondary clearance levels
does not automatically trigger the re-cleaning. In the event re-cleaning is required, re-sampling shall
be performed immediately upon completion of the cleaning.