NYC 9/11 Public Portal Document
AIRTEK Date: 11/26/01 Proj Num: 01-1212
ENVIRONMENTAL Page: 25
AIR SAMPLING RESULTS
CORD Code: FV
As
--Types of Project-- Address:LIONS HEAD 110
DEVELOPEMENT LLC
110 CHURCH STREET
I State: Zip:
Date Analyzed: 12/01/01
Sample V -1126-19 FV -1126-20 V -1126-21 FV -1126-22 FV -1126-23
Location IWA,1ST FL. IWA,2ND FL. FTA,BSMT. IWA,BSMT IWA,SUB BSMT
J. TO STAIR ELEVATOR BANK DJ. TO ORTH CENTER RAMP AREA
ASE TO BSMT 4 LEVATOR SIDE OF RM
HAFT 4
I ctivity RE ABATEMENT PRE ABATEMENT RE ABATEMENT PRE ABATEMENT PRE ABATEMENT
Personal - -
vg Flow 7.0 7.0 7.0 7.0 7.0
1 Date 1/26/01 11/26/01 1/26/01 11/26/01 11/26/01
rime On 01:39P 01:41P 1:46P 01:49P 01:52P
ime Off 05:19P 05:21P 5:06P 05:09P 05:12P
I of Time 20 min 220 min 00 min 200 min 200 min
of Vol L540 ltr 1540 ltr 400 ltr 1400 ltr 1400 ltr
V Cnt
Fibr
Per Fld •335 .005 .18 .04 .01
I ibr Cnt
Fibr
Per CC 0.0107 < 0.0018 .0413 0.0019 < 0.0019
omments
ANALYSIS: NIOSH 74
Authorized Signatu
I
I
I
NYC-WTC 000098159