NYC 9/11 Public Portal Document
Attn: Fred Burkhardt Received: 9/16/02 8:00:00 AM
ATC Associates Inc. ATC Group #: 8841
104 East 25th Street Analysis Date: 9/18/02
New York NY 10010
Fax: (212) 353-3599 Phone: (212) 353-8280
Project: DEP Cleaan-up Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample Volume Analyzed Ash Type(s) 0.5,u-S 5,a (S/cc) (S/mm') (S/cc) Notes
20 2390.00 0.0450 0 CHRYSOTILE 1 0 0.0036 22.24 0.0036
8841 -17
21 2390.00 0.0450 0 CHRYSOTILE 1 1 0.0036 44.48 0.0072
8841 -18
22 2400.00 0.0450 0 None Detected 0 0 0.0036 <22.24 <0.0036
8841 -19
23 2410.00 0.0450 0 CHRYSOTILE 2 0 0.0036 44.48 0.0071
8841 -20 -
24 2000.00 0.0450 0 None Detected 0 0 0.0043 <22.24 <0.0043
8841 -2/
25. 2000.00 0.0450 0 None Detected 0 0 0.0043 <22.24 <0.0043
8841 -22
26 2000.00 Not Analyzed Overloaded with particulates
8841 -23
Z7 2000.00 0.0450 0 CHRYSOTILE 1 0 0.0043 22.24 0.0043
8$4/ -24
28 1990.00 0.0450 0 CHRYSOTILE 0 1 0.0043 22.24 0.0043
884/ -25
ROMAN PEYSA MICHAEL A. GORYCKI, Ph.D.
Analyzed by: pproved by:
Disclaimer. The laboratory is not responsible for data reported in structures/cc, which is dependent on volume coil ed by non-laboratory personnel. Thi is only responsible
for data reported in structures/mm=. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
Page 3 of 3
NYC-WTC 000097251
OCR can misread numbers and units. Confirm readings against the page image before using them.