NYC 9/11 Public Portal Document
AMBIENT GROUP, INC.
10 MORRIS AVENUE
GLEN COVE, NY 11542
DUST CHARACTERIZATION LABORATORY DATA REPORT
PROJECT ID: 211358 DATE COLLECTED: 10/20/01
CLIENT: J. RESNICK & SONS, INC. DATE RECEIVED: 10120/01
LOCATION: 75 PARK PLACE DATE ANALYZED: 10121/01
TECHNICIAN: PETER SCHORK
FIELD ID SAMPLE PERCENT OF
LABORATORY ID DESCRIPTION CONSTITUENTS SAMPLE
10-20-211358-51 CELLULOSE 10.0%
DB3009 LOBBY: RECEPTION A/C, SUPPLY ACCESS FIBER GLASS 20.0%
CEMENT DUST 10.0%
GRAVEL ROAD DUST 30.0%
CARBON PARTICLES 30.0%
TOTAL 100.0%
Signed for Ambient Group Inc. by,
TAREK FATA
ND - None Detected. NA - Not Analyzed, Thera are two (2) types of dust sample submitted for analysW. Settled - Samples submitted on tape/bulk Airborne • Samples submhted
In AY-0Csh cassettes, MI results dledosed In this report relate only to the horns tested. No reproducdon of all of any pardon of this report shall occur wlmout wrdtee approwl
of AmbWt Group Inc. Unlea otherwise directed by the Client. Ambient Group Inc, will tebdn the samples listed In this report foriNe (5) days, afterwhkh Sine they may be dIsposed
of In accordance whh applicable regulabons.
NYC-WTC 000096112