NYC 9/11 Public Portal Document
AMBIENT GROUP, INC.
10 MORRIS AVENUE
GLEN COVE, NY 11542
DUST CHARACTERIZATION LABORATORY DATA REPORT
PROJECT ID: 211358 DATE COLLECTED: 10/20/01
CLIENT: J. RESNICK & SONS, INC. DATE RECEIVED: 1020/01
LOCATION: 75 PARK PLACE DATE ANALYZED: 10/20/01
TECHNICIAN: PETER SCHORK
FIELD ID SAMPLE PERCENT OF
LABORATORY ID DESCRIPTION CONSTITUENTS SAMPLE
10-20-211358-18 CELLULOSE 30.0%
DB2976 9TH FLOOR: SW CORNER, ABOVE CEILING COTTON 5.0%
WOOL 5.0%
SYNTHETIC FIBER 10.0%
FIBER GLASS 20.0%
CEMENT DUST 10.0%
GRAVEL ROAD DUST 10.0%
CARBON PARTICLES 10.0%
TOTAL 100.0%
Signed far Ambient Group Inc. by,
TAREK FATA
ND - None Detected, NA Not Analyzed, Thee are two (2) types of dust sample submstad for analyses Sealed = Samples
submttad on tapdbulk Airborne - Samples submfted
a
in Air-0-0@11 Cassette. All resurys dlacbaed In Mm report relate only to the Rams tested. NO ropeducton of
all or any portion of this report still occur without written approval
ofAmbient Group trio. Unless oUrrwfse d1rected by the Client. Amblent Group Inc. will retain the amples listed In this
reportforfive (5) days, after Which the they may be disposed
of In accordance with applicable regulatlona_
NYC-WTC 000096079