NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed)

Signal #1 : C:\MSDCHEM\1\DATA\5O8\O112O1\CHLC1.D\ECD1A.CH Vial: 4 Signal #2 : C:\MSDCHEM\1\DATA\508\011201\CHLC1.D\EGD2B.CH Acq On : 01 Dec 2001 4:13 pm Operator: Nefliu Sample : chlordane ccvl Inst : Instrume Mise : Multiplr: 1.00 IntFile Signal #1: EVENTS.E IntFile Signal #2: events2.e Quant Time: Dec 03 08:09:43 2001 Quant Results File: 011201C.RES Quant Method : C:\MSDCHEM\l\METHODS\0il201C.M (Chemstation Integrator) Title : 508 Chlorinated Pesticides - Chlordane Last Update : Sat Dec 01 09:27:08 2001 Response via : Initial Calibration DataAcq Meth : 508.M

Volume Inj. Signal #1 Phase Signal #2 Phase: Signal #1 Info Signal #2 Info : Compound RT#1 RT#2 Resp#l Resp#2 ug/1 ug/1

System Monitoring Compounds 4) s 2,4-DDD SURROGAT 14.39 14.89 7602914 11550828 0.003 0.005 # Spiked Amount 0.200 Recovery- 1.50% 2.50% Target Compounds 1) Chlordane Peak 1 11.12 11.32 102.4E6 69791330 0.436 0.397 2) Chlordane Peak 2 12.18 12.47 97128297 74472497 0.435m 0.423 3) Chlordane Peak 3 13.55 13.84 239.4E6 201.4E6 0.394m 0.378

\

(f)=RT Delta > 1/2 Window {#)=Amounts differ by > 25% (m)=manual int. CHLCl.D 011201T.M Tue Dec 18 10:45:13 2001 Page 1

NYC-WTC_000092381

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000092381Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →