NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 68/508 X 11/3/01 A 11/30/01
Document / 7 pages

Toxaphene pesticide analysis, EPA Method 508, Nov 2001

Machine-extracted title · confidence 100%

Gas chromatography analysis of toxaphene peaks using EPA Method 508 with multiple chromatographic signals and quality control data from November 2001.

NYC-WTC_000092202–000092208

Folder label: “508 X 11/3/01 A 11/30/01

Page image
Scanned page image, NYC-WTC_000092204
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report Signal #1 : C:\HPCHEM\1\DATA\508F\011130D\TOXC2.D\ECD1A.CH Vial: 18- Signal #2 : C:\HPCHEM\1\DATA\508F\011130D\TOXC2.D\ECD2B.CH Acq On : 30 Nov 2001 10:58 pm Operator Nefliu Sample : tox ic2 Inst 104 Mise : Multiplr 1.00 IntFile Signal #1: events.e IntFile Signal #2: events2.e Quant Time: Dec 11 8:44 2001 Quant Results File: 011204T.RES

Quant Method : C:\HPCHEM\1\METHODS\508\011204T.M (Chemstation Integrator) Title : 508 CHLORINATED PESTICIDES TOXAPHENE7/28/99 Last Update : Fri Nov 09 16:13:01 2001 Response via : Multiple Level Calibration DataAcq Meth : 508F2.M Volume Inj. Signal #1 Phase Signal #2 Phase: Signal #1 info Signal #2 Info : TOXC2.D\ECD1A ”“88^ 26000 S 24000 S 22000

20000

18000

16000

14000

12000 8 § 10000 A 6000 t—\j^ 8000 A UJ UJ UJUJ K 2 z z zz UJ CZ) UJ UJ UJUJ I Q I X XX 4000- I Q < Time 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 Response_ TOXC2.D\ECD2B

40000 iS S 35000

30000

25000

20000 S S 15000 E5 §

10000 A UJ UJ lU UJ UJ 5000 3Q 5g X I gg gXII § n iee----- Time 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00

TOXC2.D 011204T.M Tue Dec 11 08:44:27 2001 Page 2

NYC-WTC_000092204

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000092204Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →