NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\l\DATA\SEP2801\22655.D Vial: 14
Acq On : 29 Sep 2001 1:11 am Operator: 209 GALOS
Sample : gc/ms unknown Inst : GC/MS 209
Mise Multiplr: 1.00
MS Integration Params: RTEINT.P
Quant Time: Oct 9 12:05 2001' Quant Results File: NP091101.RES
Quant Method : C:\HPCHEM\1\METHODS\NP091101.M (RTE Integrator)
Title : 209 625/TCLP calibration table 7/16/01
Last Update : Thu Sep 13 12:47:04 2001
Response via : Initial Calibration
DataAcq Meth : NP091101
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.79 152 480939 20.00 ug/1 -0.12
19) Naphthalene-d8 15.41 136 1888032 20.00 ug/1 -0.12
31) Acenaphthene-dlO 20.69 164 878573 20.00 ug/1 -0.12
49) Phenanthrene-dlO 25.12 188 1252943 20.00 ug/1 -0.12
59) Chrysene-dl2 33.16 240 933634 20.00 ug/1 -0.12
68) Perylene-dl2 37.28 264 707848 20.00 ug/1 -0.14
System Monitoring Compounds
4) 2-Fluorophenol 0.00 112 0 0.00 ug/1
Spiked Amount 75.000 Recovery = 0.00%
5) Phenol-d5 0.00 99 0 0.00 ug/1
Spiked Amount 75.000 Recovery = 0.00%
6) 2-Chlorophenol-d4 0.00 132 0 0.00 ug/1
Spiked Amount 75.000 Recovery = 0.00%
7) 1,2-Dichlorobenzene-d4 12.31 152 5242 0.22 ug/1 -0.12
Spiked Amount 50.000 Recovery = 0.44%
20) Nitrobenzene-d5 0.00 82 0 0.00 ug/1
Spiked Amount 50.000 Recovery = 0.00%
32) 2-Fluorobiphenyl 18.83 172 1802 0.03 ug/l 0.02
Spiked Amount 50.000 Recovery = 0.06%
33) 2,4,6-Tribromophenol 0.00 330 0 0.00 ug/1
Spiked Amount 75.000 Recovery = 0.00%
62) Terphenyl-dl4 0.00 244 0 0.00 ug/1
Spiked Amount 50.000 Recovery = 0.00%
Target Compounds Qvalue
2) Pyridine 5.25 79 100 N.D-r-
3) N-nitroso-dimethyl amine 0.00 74 0 N.D.
8) Phenol 0.00 94 0 N.D.
9) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
10) 2-Chlorophenol 0.00 128 0 N.D.
11) 1,3-Dichlorobenzene 0.00 146 0 N.D.
12) 1,4-Dichlorobenzene 0.00 146 0 N.D.
13) 1,2-Dichlorobenzene 0.00 146 0 N.D.
14) 2-Methylphenol 0.00 108 0 N.D.
15) 2,2'-oxybis(1-Chloropropan 0.00 45 0 N.D.
16) 3&4-Methylphenol 0.00 108 0 N.D.
(#) = qualifier out of range (m) = manual integration
22655.D NP091101.M Tue Oct 09 12:05:47 2001 Page 1
NYC-WTC_000087327
OCR can misread numbers and units. Confirm readings against the page image before using them.