Method 200.8 - Summary Report Sample ID: AD31637 Sample Date/Time: Tuesday, January 08, 2002 15:07:49 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\AD31637.1904 Sample Prep Volume (ml): Initial Sample Quantity (mg): Aliquot Volume (ml): Diluted To Volume (ml):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 13.667 8.449 0.000 0.00530 26.34 ug/L I: Sc-1 45 662822.984 3.048 662822.984 ug/L I Cr 52 13083.544 2.836 0.006 0.34105 13.10 ug/L I Cr 53 1250.099 4.989 0.001 0.49920 12.81 ug/L I Mn 55 533736.964 5.997 0.806 28.43409 8.89 ug/L I Ni 60 913.388 5.077 0.001 0.26736 2.70 ug/L I Cu 63 7036.461 2.891 0.005 0.45680 1.72 ug/L L Cu 65 3433.016 2.297 0.002 0.43591 11.37 ug/L r Zn 66 2283.977 6.195 0.014 0.74358 8.68 ug/L I Zn 67 572.691 11.589 0.004 1.07069 15.15 ug/L I Zn 68 2250.635 6.581 0.015 1.07910 8.63 ug/L I; Ge 72 115305.787 0.176 115305.787 ug/L I As 75 1652.599 9.091 0.010 0.52572 13.31 ug/L I Se 77 189.671 8.002 0.001 0.31534 25.00 ug/L L Se 82 387.679 12.302 0.001 0.44728 44.61 ug/L r Ag 107 759.706 14.495 0.000 0.03943 22.75 ug/L I: In 115 1308692.852 1.401 1308692.852 ug/L I Sb 121 793.043 7.967 0.001 0.09465 7.32 ug/L L Sb 123 611.585 8.775 0.000 0.09655 8.09 ug/L r Ba 135 34951.437 2.535 0.019 13.51494 4.86 ug/L I Ba 137 61159.654 0.715 0.034 13.49759 2.23 ug/L b Ho 165 1787183.850 2.298 1787183.850 ug/L Tl 205 384.345 14.722 0.000 0.00623 33.40 ug/L L Pb 208 4601.508 2.550 0.000 0.00885 34.53 ug/L
Sample ID: AD31637 Report Date/Time: Tuesday, January 08, 2002 15:09:21 Page 1
NYC-WTC_000086353
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085591
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000086256
Single unreadable page from the DEP Box 66 collection associated with the January 8, 2002 batch.
Filed in the same folder
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similar indexed content