NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
NYC-WTC_000086257–000086384Folder label: “NEWQ 01/08/2002 31404 - 31662”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: AD31585 Sample Date/Time: Tuesday, January 08, 2002 14:10:49 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\AD31585.1893 Sample Prep Volume (ml): Initial Sample Quantity (mg): Aliquot Volume (ml): Diluted To Volume (ml):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 9.000 11.111 -0.000 -0.00375 46.22 ug/L I: Se-I 45 666552.261 1.045 666552.261 ug/L I Cr 52 12757.410 2.783 0.005 0.30656 7.46 ug/L I Cr 53 1790.528 6.874 0.002 0.89118 10.69 ug/L 1 Mn 55 562327.634 6.010 0.843 29.73347 5.59 ug/L I Ni 60 995.065 5.853 0.001 0.29339 7.85 ug/L I Cu 63 6969.741 2.074 0.005 0.44139 2.58 ug/L L Cu 65 3420.678 3.540 0.002 0.42569 5.85 ug/L r Zn 66 1159.752 4.959 0.005 0.25349 16.68 ug/L 1 Zn 67 391.346 3.403 0.002 0.64130 6.93 ug/L I Zn 68 1464.800 5.639 0.009 0.61487 13.31 ug/L I: Ge 72 113048.599 3.570 113048.599 ug/L I As 75 1547.117 6.503 0.009 0.49202 11.07 ug/L I Se 77 225.672 2.951 0.001 0.53211 12.95 ug/L L Se 82 356.011 5.080 0.001 0.34758 31.14 ug/L r Ag 107 180.670 4.154 -0.000 -0.01250 2.68 ug/L In 115 1318319.195 2.252 1318319.195 ug/L I Sb 121 474.017 4.916 0.000 0.05248 4.80 ug/L L Sb 123 376.406 11.017 0.000 0.05600 10.87 ug/L r Ba 135 36189.598 1.673 0.020 13.73673 2.38 ug/L I Ba 137 61983.604 2.116 0.034 13.43059 2.28 ug/L I: Ho 165 1819957.250 2.125 1819957.250 ug/L I Tl 205 182.337 6.427 -0.000 -0.00113 47.37 ug/L L Pb 208 2242.130 3.616 -0.001 -0.04663 3.50 ug/L
Sample ID: AD31585 Report Date/Time: Tuesday, January 08, 2002 14:12:20 Page 1
NYC-WTC_000086331
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085591
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000086256
Single unreadable page from the DEP Box 66 collection associated with the January 8, 2002 batch.
Filed in the same folder
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similar indexed content