NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
NYC-WTC_000086257–000086384Folder label: “NEWQ 01/08/2002 31404 - 31662”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: AD31662 Sample Date/Time: Tuesday, January 08, 2002 15:47:27 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\AD31662.1916 Sample Prep Volume (mL): Initial Sample Quantity (mg): Aliquot Volume (ml): Diluted To Volume (ml):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 8.000 43.301 -0.000 -0.00498 141.50 ug/L 1: Se-I 45 640075.997 1.139 640075.997 ug/L I Cr 52 14147.502 6.149 0.008 0.47363 16.49 ug/L I Cr 53 1673.838 3.526 0.002 0.85613 5.79 ug/L I Mn 55 539435.757 4.346 0.842 29.71748 5.35 ug/L I Ni 60 974.729 2.892 0.001 0.29995 2.91 ug/L I Cu 63 6838.640 0.985 0.005 0.46332 1.46 ug/L L Cu 65 3330.645 5.879 0.002 0.43994 15.21 ug/L r Zn 66 1355.782 6.972 0.007 0.37196 14.60 ug/L I Zn 67 420.347 4.901 0.003 0.76477 4.69 ug/L I Zn 68 1492.804 2.383 0.010 0.67616 5.73 ug/L I: Ge 72 107853.196 1.691 107853.196 ug/L I As 75 1605.892 5.966 0.010 0.55485 6.64 ug/L I Se 77 214.671 0.712 0.001 0.52730 4.42 ug/L L Se 82 389.012 7.357 0.001 0.56270 18.91 ug/L r Ag 107 136.002 7.677 -0.000 -0.01573 6.33 ug/L I; In 115 1241892.210 0.735 1241892.210 ug/L I Sb 121 451.016 4.429 0.000 0.05312 5.82 ug/L L Sb 123 355.018 4.493 0.000 0.05615 5.83 ug/L r Ba 135 34139.034 3.287 0.020 13.87361 5.02 ug/L I Ba 137 59758.392 1.541 0.035 13.86583 3.98 ug/L I: Ho 165 1701010.927 3.217 1701010.927 ug/L Tl 205 151.669 0.761 -0.000 -0.00184 7.80 ug/L L Pb 208 3645.325 2.309 -0.000 -0.00893 43.48 ug/L
Sample ID:AD31662 Report Date/Time: Tuesday, January 08, 2002 15:48:58 Page 1
NYC-WTC_000086377
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085591
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000086256
Single unreadable page from the DEP Box 66 collection associated with the January 8, 2002 batch.
Filed in the same folder
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similar indexed content