Method 200.8 - Summary Report Sample ID: CCV CAL BK Sample Date/Time: Monday, January 07, 2002 16:17:27 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\CCV CAL BK.1836 Sample Prep Volume (mL): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 11.667 38.651 -0.000 -0.00377 272.54 ug/L I; Sc-1 45 661462.197 4.295 661462.197 ug/L I Cr 52 18533.538 83.061 0.013 0.71103 195.35 ug/L I Cr 53 1131.415 4.515 0.000 0.20806 33.31 ug/L I Mn 55 935.057 4.356 -0.000 -0.00604 72.12 ug/L I Ni 60 112.668 2.712 -0.000 -0.00531 49.26 ug/L I Cu 63 1047.738 4.437 -0.000 -0.00305 7.39 ug/L L Cu 65 530.021 5.066 -0.000 -0.00687 222.35 ug/L r Zn 66 795.043 4.780 0.000 0.00720 259.58 ug/L i Zn 67 200.338 4.035 0.000 0.05238 36.38 ug/L I Zn 68 590.358 1.153 -0.000 -0.00268 100.51 ug/L I: Ge 72 114486.867 0.429 114486.867 ug/L I As 75 529.797 16.071 0.000 0.01528 251.20 ug/L 1 Se 77 158.003 9.366 0.000 0.10397 72.16 ug/L L Se 82 315.342 9.828 0.000 0.07221 168.86 ug/L r Ag 107 217.338 7.934 -0.000 -0.01922 8.42 ug/L In 115 1322021.904 1.018 1322021.904 ug/L I Sb 121 97.001 12.155 -0.000 -0.00106 130.18 ug/L L Sb 123 76.275 23.315 -0.000 -0.00045 601.16 ug/L r Ba 135 326.009 4.011 0.000 0.00457 47.76 ug/L I Ba 137 555.689 5.782 -0.000 -0.00293 266.58 ug/L I: Ho 165 1833373.921 2.530 1833373.921 ug/L 1 T1 205 301.675 6.674 -0.000 -0.00089 107.70 ug/L L Pb 208 5006.596 0.942 -0.000 -0.00535 77.14 ug/L
Sample ID: CCV CAL BK Report Date/Time: Monday, January 07, 2002 16:18:58 Page 1
NYC-WTC_000086250
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085591
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000086173
A single-page Department of Environmental Protection document covering World Trade Center site batches from January 7, 2002.
Filed in the same folder
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
Similar indexed content