NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
NYC-WTC_000086174–000086255Folder label: “NEWQ 01/07/2002 31249 - 31403”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: CCV STD1 30 PPB Sample Date/Time: Monday, January 07, 2002 15:29:58 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\CCV STD1 30 PPB.1821 Sample Prep Volume (ml): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 15310.370 1.637 0.023 31.16421 3.72 ug/L Sc-1 45 667567.081 3.217 667567.081 ug/L I Cr 52 365297.784 2.854 0.532 29.38969 4.42 ug/L I Cr 53 42123.483 2.161 0.062 28.60637 3.05 ug/L I Mn 55 562755.711 3.320 0.842 29.24033 6.00 ug/L I Ni 60 87864.303 2.653 0.132 28.46062 4.55 ug/L I Cu 63 209132.269 0.614 0.312 30.08817 3.89 ug/L L Cu 65 103925.819 1.831 0.155 30.75538 4.86 ug/L r Zn 66 69018.421 1.912 0.590 31.31111 3.07 ug/L I Zn 67 12463.668 2.988 0.106 31.92457 2.13 ug/L I Zn 68 50172.633 2.609 0.429 30.70098 3.79 ug/L i; Ge 72 115671.452 1.126 115671.452 ug/L I As 75 68479.706 1.337 0.588 29.87024 2.07 ug/L I Se 77 6168.487 0.793 0.052 29.02893 1.87 ug/L L Se 82 8136.055 2.409 0.068 29.62074 3.52 ug/L r Ag 107 342814.812 0.933 0.257 30.72407 1.84 ug/L I: In 115 1334037.356 1.574 1334037.356 ug/L Sb 121 253910.154 1.649 0.190 29.85449 3.01 ug/L L Sb 123 194563.197 2.616 0.146 29.33965 1.19 ug/L r Ba 135 76699.320 1.173 0.042 29.19120 2.18 ug/L I Ba 137 133567.112 1.008 0.073 29.42689 1.08 ug/L l> Ho 165 1820018.896 2.018 1820018.896 ug/L I Tl 205 880357.577 3.280 0.484 30.30075 3.47 ug/L L Pb 208 1268184.184 1.855 0.694 32.03758 0.35 ug/L
Sample ID: CeV STD1 30 PPB Report Date/Time: Monday, January 07, 2002 15:31:30 Page 1
NYC-WTC_000086220
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085591
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000086173
A single-page Department of Environmental Protection document covering World Trade Center site batches from January 7, 2002.
Filed in the same folder
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
Similar indexed content