NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
NYC-WTC_000086174–000086255Folder label: “NEWQ 01/07/2002 31249 - 31403”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: LFB 50 PPB Sample Date/Time: Monday, January 07, 2002 14:32:24 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\LFB 50 PPB.1806 Sample Prep Volume (ml): Initial Sample Quantity (mg): Aliquot Volume (ml): Diluted To Volume (ml):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Sc-1 Be 9 24390.293 4.347 0.037 50.38795 5.98 ug/L I: 45 658040.254 2.710 658040.254 ug/L I Cr 52 619837.767 0.942 0.927 51.21376 3.01 ug/L Cr 53 71702.387 0.915 0.108 49.82064 2.60 ug/L I Mn 55 949485.735 1.918 1.442 50.05521 3.41 ug/L I Nt 60 151458.242 3.747 0.230 49.81837 6.42 ug/L Cu 63 340255.184 2.197 0.516 49.73103 1.74 ug/L L Cu 65 168282.791 3.432 0.255 50.61361 5.02 ug/L r Zn 66 111551.013 2.776 0.951 50.46506 2.39 ug/L I Zn 67 20068.332 1.850 0.171 51.34750 2.60 ug/L I Zn 68 83224.821 2.107 0.710 50.81768 3.46 ug/L I: Ge 72 116473.298 1.373 116473.298 ug/L I As 75 117665.372 2.135 1.006 51.13665 3.49 ug/L I Se 77 10799.523 3.056 0.092 50.94935 1.78 ug/L L Se 82 13688.435 0.927 0.115 50.24880 2.11 ug/L r Ag 107 588924.926 2.200 0.432 51.68681 3.61 ug/L I: In 115 1363270.056 1.827 1363270.056 ug/L I Sb 121 437869.761 0.703 0.321 50.38211 1.41 ug/L L Sb 123 334468.560 0.973 0.245 49.38416 2.66 ug/L r Ba 135 134651.993 1.284 0.073 50.80565 1.99 ug/L I Ba 137 230018.833 2.242 0.125 50.27109 4.74 ug/L I: Ho 165 1839105.393 2.527 1839105.393 ug/L I Tl 205 1451495.931 0.810 0.789 49.45607 2.18 ug/L L Pb 208 1999536.060 1.519 1.085 50.08837 3.44 ug/L
Sample ID: LFB 50 PPB Report Date/Time: Monday, January 07, 2002 14:33:56 Page 1
N YC-WTC_000086190
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085591
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000086173
A single-page Department of Environmental Protection document covering World Trade Center site batches from January 7, 2002.
Filed in the same folder
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
Similar indexed content