ICP-MS heavy metals analysis, Jan 4, 2002

Machine-extracted title · confidence 100%

Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.

NYC-WTC_000086120–000086172

Folder label: “NEWQ 01/04/2002 31021 - 31135

Page image
Scanned page image, NYC-WTC_000086124
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Method 200.8 - Summary Report Sample ID: Standard 2 Sample Date/Time: Friday, January 04, 2002 17:06:02 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\Standard 2.1747 Sample Prep Volume (ml): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (ml);

Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Sc-1 Be 9 23211.493 0.257 0.044 59.77786 1.47 ug/L I: 45 530057.305 1.588 530057.305 ug/L Cr 52 595461.422 1.722 1.105 59.86198 1.50 ug/L I Cr 53 71486.490 2.794 0.134 60.04900 2.24 ug/L I Mn 55 944842.388 0.298 1.782 59.82412 1.75 ug/L I Ni 60 149472.468 2.569 0.282 59.53395 2.68 ug/L I Cu 63 339112.286 3.743 0.634 59.41264 5.37 ug/L L Cu 65 163969.171 4.971 0.307 59.32603 6.66 ug/L r ZnZn 66 104979.132 1.594 1.059 59.70102 1.15 ug/L I 67 18949.587 1.169 0.191 59.70252 1.63 ug/L I Zn 68 77213.342 1.594 0.779 59.92447 2.00 ug/L Ge 72 98708.319 0.643 98708.319 ug/L I As 75 115275.705 0.342 1.163 59.88039 0.91 ug/L I Se 77 10304.940 0.244 0.103 59.78415 0.41 ug/L L Se 82 13451.747 1.264 0.134 59.87017 0.66 ug/L r Ag 107 565505.678 2.422 0.496 59.93139 1.16 ug/L I; In 115 1139693.047 1.525 1139693.047 ug/L I Sb 121 449077.941 0.709 0.394 59.98366 0.85 ug/L L Sb 123 344802.763 1.579 0.303 60.03355 1.25 ug/L r Ba 135 134046.936 1.899 0.086 59.94235 1.24 ug/L I Ba 137 236192.022 0.727 0.151 60.05320 0.27 ug/L I: Ho 165 1561582.251 0.750 1561582.251 ug/L I Tl 205 1417089.261 3.542 0.907 59.69332 2.90 ug/L L Pb 208 1902019.353 2.305 1.216 59.60017 2.27 ug/L

Sample ID; Standard 2 Report Date/Time: Friday, January 04, 2002 17:07:33 Page 1

NYC-WTC_000086124

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000086124Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

ICP-MS summary report, Jan 4 2002 · Box DEP Box 66

NYC-WTC_000085362

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.998

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 3 2002 · Box DEP Box 66

NYC-WTC_000085227

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.998

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 10 2002 · Box DEP Box 66

NYC-WTC_000085591

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.997

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →