ICP-MS heavy metals analysis, Jan 4, 2002

Machine-extracted title · confidence 100%

Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.

NYC-WTC_000086120–000086172

Folder label: “NEWQ 01/04/2002 31021 - 31135

Page image
Scanned page image, NYC-WTC_000086157
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Method 200.8 - Summary Report Sample ID: AD31131 Sample Date/Time: Friday, January 04, 2002 18:15:08 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: Sample Prep Volume (ml): Initial Sample Quantity (mg): Aliquot Volume (ml): Diluted To Volume (ml):

Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 11.667 27.553 0.000 0.00700 118.61 ug/L I: Sc-1 45 556677.200 2.511 556677.200 ug/L I Cr 52 9972.901 1.586 -0.000 -0.01263 101.03 ug/L I Cr 53 1538.812 2.272 0.002 0.69003 7.85 ug/L I Mn 55 378125.394 0.900 0.678 22.77759 1.73 ug/L I Ni 60 883.718 1.156 0.001 0.28462 3.61 ug/L Cu 63 26900.393 4.375 0.043 3.98262 7.22 ug/L L Cu 65 12907.958 2.867 0.020 3.92854 6.06 ug/L r Zn 66 2338.324 2.136 0.019 1.05313 2.32 ug/L I Zn 67 570.357 2.220 0.005 1.42089 3.97 ug/L I Zn 68 2295.313 3.381 0.019 1.48144 3.36 ug/L I: Ge 72 101176.948 0.979 101176.948 ug/L I As 75 1349.884 5.092 0.009 0.46047 7.02 ug/L I Se 77 214.671 2.808 0.001 0.44054 5.48 ug/L L Se 82 300.675 1.168 0.000 0.21174 2.07 ug/L r Ag 107 152.003 9.045 -0.000 -0.00718 17.27 ug/L I: In 115 1145201.556 1.360 1145201.556 ug/L I Sb 121 410.347 2.938 0.000 0.04410 4.92 ug/L L Sb 123 350.078 4.638 0.000 0.05287 5.76 ug/L r Ba 135 30648.884 0.396 0.019 13.40038 1.05 ug/L I Ba 137 54184.544 0.745 0.034 13.47152 0.42 ug/L I; Ho 165 1588033.982 0.670 1588033.982 ug/L I Tl 205 97.668 13.205 0.000 0.00003 1508.40 ug/L L Pb 208 7311.217 0.479 0.002 0.10221 0.68 ug/L

Sample ID: AD31131 Report Date/Time: Friday, January 04, 2002 18:16:39 Page 1

NYC-WTC_000086157

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000086157Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

ICP-MS summary report, Jan 4 2002 · Box DEP Box 66

NYC-WTC_000085362

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.998

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 3 2002 · Box DEP Box 66

NYC-WTC_000085227

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.998

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 10 2002 · Box DEP Box 66

NYC-WTC_000085591

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.997

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →