NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 66/NEWE January 18, 2002 AE01036 - AE01405 Batches 16521 16522 copies made
Document / 38 pages

ICP-MS summary report, Jan 18 2002

Machine-extracted title · confidence 100%

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Manganese, Indium, and Antimony.

NYC-WTC_000085865–000085902

Folder label: “NEWE January 18, 2002 AE01036 - AE01405 Batches 16521 16522 copies made

Page image
Scanned page image, NYC-WTC_000085873
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Method 200.8 - Summary Report Sample ID: LRB Sample Date/Time: Friday, January 18, 2002 14:43:41 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWE200.8.mth Dataset File: d:\elandata\Dataset\daily performance\LRB.2397 Sample Prep Volume (mL): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (mL):

Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 15.667 3.685 0.000 0.00142 61.47 ug/L |> Sc-1 45 749508.205 0.845 749508.205 ug/L L Mn 55 1283.437 1.592 0.000 0.00474 30.22 ug/L r> In 115 1685109.006 1.660 1685109.006 ug/L I Sb 121 441.348 7.368 0.000 0.03564 10.46 ug/L L Sb 123 340.017 8.048 0.000 0.03360 12.04 ug/L r> Ho 165 2618057.315 1.896 2618057.315 ug/L L Tl 205 1071.407 4.249 -0.000 -0.00588 10.19 ug/L

QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 i> sc-1 45 98.625 L Mn 55 r> In 115 99.147 I Sb 121 L Sb 123 r> Ho 165 102.633 L Tl 205 Calibration Analyte MassCurve Type Correlation Coefficient r Be 9Linear Thru Zero 0.999980 i> Sc-1 45Linear Thru Zero L Mn 55Linear Thru Zero 1.000000 r> In 115Linear Thru Zero I Sb 121 Linear Thru Zero 0.999978 L Sb 123Linear Thru Zero 0.999969 r> Ho 165Linear Thru Zero L Tl 205Linear Thru Zero 0.999755

Sample ID: LRB Report Date/Time: Friday, January 18, 2002 14:44:14 Page 1

NYC-WTC_000085873

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000085873Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

ICP-MS summary report, Jan 14 2002 · Box DEP Box 66

NYC-WTC_000085539

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Manganese, Indium, and Antimony.

1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 4 2002 · Box DEP Box 66

NYC-WTC_000085362

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.969

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 10 2002 · Box DEP Box 66

NYC-WTC_000085591

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.969

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 3 2002 · Box DEP Box 66

NYC-WTC_000085227

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.969

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →