NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
NYC-WTC_000085591–000085724Folder label: “NEW Q 1/10/2002 AD 31663 - AE00559 Batches 16363 16364 16372 16374 copies made”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: AE00276 Sample Date/Time: Thursday, January 10, 2002 12:17:38 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\AE00276.1970 Aliquot Volume (mL): Diluted To Volume (ml):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 12.000 38.188 0.000 0.00484 207.92 ug/L I: Sc-1 45 618008.325 2.021 618008.325 ug/L I Cr 52 12232.014 1.867 0.005 0.29198 0.66 ug/L I Cr 53 1772.857 1.972 0.002 0.98816 5.53 ug/L I Mn 55 681598.602 4.524 1.102 38.74782 3.17 ug/L I Ni 60 1084.076 12.069 0.002 0.33267 15.46 ug/L I Cu 63 7002.436 4.608 0.010 0.89861 3.02 ug/L L Cu 65 3251.614 1.763 0.005 0.80465 3.14 ug/L r Zn 66 1144.750 4.718 0.008 0.38465 12.56 ug/L I Zn 67 416.347 4.379 0.003 0.82574 4.02 ug/L I Zn 68 1345.447 7.661 0.010 0.68399 15.15 ug/L I: Ge 72 111896.866 4.669 111896.866 ug/L I As 75 1510.624 3.667 0.009 0.45469 1.71 ug/L I Se 77 241.006 2.591 0.001 0.50556 5.86 ug/L L Se 82 352.010 5.675 0.001 0.24853 27.39 ug/L r In Ag 107 152.669 5.335 -0.001 -0.06585 1.79 ug/L I: 115 1258121.151 2.833 1258121.151 ug/L I Sb 121 413.014 8.402 0.000 0.02377 23.46 ug/L L Sb 123 332.096 5.436 0.000 0.02745 8.33 ug/L r Ba 135 34373.604 3.892 0.019 13.39296 3.85 ug/L I Ba 137 60646.975 2.494 0.034 13.69501 4.19 ug/L I: Ho 165 1776363.282 2.221 1776363.282 ug/L I Tl 205 230.005 6.580 -0.000 -0.00952 4.65 ug/L L Pb 208 3876.362 3.694 0.001 0.03966 13.91 ug/L
Sample ID: AE00276 Report Date/Time: Thursday, January 10, 2002 12:19:10 Page 1
NYC-WTC_000085665
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000085590
Document from DEP Box 66 folder NEWQ dated January 14, 2002; content is illegible due to OCR errors.
Filed in the same folder
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content