NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
NYC-WTC_000085591–000085724Folder label: “NEW Q 1/10/2002 AD 31663 - AE00559 Batches 16363 16364 16372 16374 copies made”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: AE00557 Sample Date/Time: Thursday, January 10, 2002 15:15:50 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\AE00557.2002 Aliquot Volume (mL): Diluted To Volume (ml):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 10.000 36.056 -0.000 -0.00074 893.90 ug/L I: Sc-1 45 656793.974 4.410 656793.974 ug/L 1 Cr 52 28052.996 7.602 0.028 1.56657 15,79 ug/L I Cr 53 4069.953 4.089 0.005 2.59608 8.01 ug/L I Mn 55 1535392.714 6.860 2.335 82.12410 3.03 ug/L I Ni 60 2551.718 6.032 0.004 0.78366 11.18 ug/L I Cu 63 125489.174 6.536 0.190 18.88215 2.57 ug/L L Cu 65 59722.821 5.271 0.091 15.61473 9.96 ug/L r Zn 66 4268.379 4.600 0.036 1.81336 3.05 ug/L I Zn 67 1044.404 2.529 0.009 2.43110 5.71 ug/L I Zn 68 4079.956 2.396 0.034 2.40097 5.50 ug/L I > Ge 72 111383.288 2.700 111383.288 ug/L I As 75 1790.199 0.862 0.011 0.58742 5.10 ug/L I Se 77 507.019 1.381 0.003 1.91387 5.78 ug/L L Se 82 416.014 2.137 0.001 0.52290 9.79 ug/L r Ag 107 137.669 5.255 -0.001 -0.06709 1.66 ug/L I: In 115 1240457.227 4.476 1240457.227 ug/L I Sb 121 591.692 2.332 0.000 0.04695 10.44 ug/L L Sb 123 455.702 6.417 0.000 0.05084 14.24 ug/L r Ba 135 70110.869 3.252 0.040 28.00456 1.38 ug/L I Ba 137 124978.058 4.097 0.072 28.98554 8.41 ug/L I: Ho 165 1734825.454 4.551 1734825.454 ug/L I Tl 205 202.671 6.735 -0.000 -0.01031 8.04 ug/L L Pb 208 68898.012 3.070 0.039 1.62707 6.91 ug/L
Sample ID: AE00557’ Report Date/Time: Thursday, January 10, 2002 15:17:22 Page 1
NYC-WTC_000085713
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086120
Lab report detailing ICP-MS analysis of water samples for beryllium, scandium, chromium, manganese, nickel, and copper on January 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067263
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 20, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067061
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067008
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 18, 2001.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000067178
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and manganese from December 19, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066601
Summary report of Method 200.8 analysis results for multiple analytes including beryllium and chromium from December 13, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066921
Summary report of Method 200.8 analysis results for multiple analytes including beryllium, chromium, and nickel from December 12, 2001.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000066458
Summary report of Method 200.8 analysis results for multiple analytes including selenium and germanium from December 13, 2001.
1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076077
Summary of water sample results for metals analysis using Method 200.8 conducted on January 24, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000085590
Document from DEP Box 66 folder NEWQ dated January 14, 2002; content is illegible due to OCR errors.
Filed in the same folder
NYC-WTC_000086174
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 7, 2002.
Similar indexed content
NYC-WTC_000085362
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content
NYC-WTC_000086257
Lab report detailing ICP-MS analysis of water samples for metals using Method 200.8 on January 8, 2002.
Similar indexed content
NYC-WTC_000085227
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
Similar indexed content