Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002
Machine-extracted title · confidence 85%
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
Method 200.8 - Summary Report
Sample ID: AE00106
Sample Date/Time: Friday, January 11,2002 15:16:10
Sample Type: Sample
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\elandata\Method\NEWE200.8.mth
Dataset File: d:\elandata\Dataset\daily performance\AE00106.2066
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL);
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 10.333 33.986 0.000 0.00039 2080.65 ug/L
|> Sc-1 45 571088.123 2.083 571088.123 ug/L
L Mn 55 2821501.719 2.571 4.941 171.28299 2.97 ug/L
r> In 115 1185769.445 1.089 1185769.445 ug/L
I Sb 121 608.693 2.008 0.000 0.07550 1.55 ug/L
L Sb 123 479.406 2.752 0.000 0.07769 1.98 ug/L
r> Ho 165 1655715.729 0.797 1655715.729 ug/L
L Tl 205 237.005 4.975 0.000 0.00145 27.08 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9
|> Sc-1 45 89.943
L Mn 55
r> In 115 89.914
I Sb 121
L Sb 123
r> Ho 165 92.187
L Tl 205
Calibration
Analyte MassCurve Type Correlation Coefficient
r Be 9Linear Thru Zero 0.999992
|> Sc-1 45Linear Thru Zero
L Mn 55Linear Thru Zero 0.999983
r> In 115Linear Thru Zero
1 Sb 121 Linear Thru Zero 0.999998
L Sb 123Linear Thru Zero 1.000000
r> Ho 165Linear Thru Zero
L Tl 205Linear Thru Zero 0.999977