Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002

Machine-extracted title · confidence 85%

ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.

NYC-WTC_000085478–000085537

Folder label: “NEWE 1/11/2002 AD 31456 - AE00110 Batches 16390 16391 16402 copies made”

Page image
Scanned page image, NYC-WTC_000085527
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Method 200.8 - Summary Report Sample ID: AE00101 Sample Date/Time: Friday, January 11, 2002 15:07:55 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWE200.8.mth Dataset File: d:\elandata\Dataset\daily performance\AE00101.2062 Sample Prep Volume (mL): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (mL):

Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit f Be 9 16.000 22.535 0.000 0.01159 75.17 ug/L |> Sc-1 45 595675.240 3.398 595675.240 ug/L L Mn 55 700181.216 3.594 1.175 40.73909 4.31 ug/L r> In 115 1231160.827 1.124 1231160.827 ug/L I Sb 121 728.036 1.584 0.001 0.08761 0.48 ug/L L Sb 123 546.738 3.798 0.000 0.08575 4.48 ug/L r> Ho 165 1682741.229 2.023 1682741.229 ug/L L Tl 205 345.677 11.288 0.000 0.00550 32.12 ug/L

QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 1> Sc-1 45 93.815 L Mn 55 r> In 115 93.356 I Sb 121 L Sb 123 r> Ho 165 93.692 L Tl 205 Calibration Analyte MassCurve Type Correlation Coefficient r Be 9Linear Thru Zero 0.999992 |> Sc-1 45Linear Thru Zero L Mn 55Linear Thru Zero 0.999983 r> In 115Linear Thru Zero I Sb 121 Linear Thru Zero 0.999998 L Sb 123 Linear Thru Zero 1.000000 r> Ho 165Linear Thru Zero L Tl 205Linear Thru Zero 0.999977

Sample ID: AE00101 Report Date/Time: Friday, January 11,2002 15:08:28 Page 1

NYC-WTC_000085527

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000085527Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

ICP-MS summary report, Jan 14 2002 · Box DEP Box 66

NYC-WTC_000085539

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Manganese, Indium, and Antimony.

1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 18 2002 · Box DEP Box 66

NYC-WTC_000085865

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Manganese, Indium, and Antimony.

1 shared topics · Same agency, volume and box · similarity 0.999

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 4 2002 · Box DEP Box 66

NYC-WTC_000085362

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.974

machine-extracted · confidence unavailable · Check page ↗
ICP-MS summary report, Jan 3 2002 · Box DEP Box 66

NYC-WTC_000085227

Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.

1 shared topics · Same agency, volume and box · similarity 0.973