Method 200.8 ICP-MS lab results, NEWE samples, Jan 11, 2002
Machine-extracted title · confidence 85%
ICP-MS analysis of water samples using Method 200.8 with elemental measurements (Be, Sc, Mn, In, Sb, Ho) and quality control replicates performed on January 11, 2002.
Method 200.8 - Summary Report
Sample ID: AD31456
Sample Date/Time: Friday, January 11, 2002 13:01:05
Sample Type: Spike - 2
Sample Description:
Number of Replicates: 3
Batch ID:
Method File: d:\elandata\Method\NEWE200.8.mth
Dataset File: d:\elandata\Dataset\daily performance\AD31456.2028
Sample Prep Volume (mL):
Initial Sample Quantity (mg):
Aliquot Volume (mL):
Diluted To Volume (mL):
Concentration Results
Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit
r Be 9 23978.497 2.094 0.038 48.03863 4.72 ug/L
|> Sc-1 45 631502.406 3.496 631502.406 ug/L
L Mn 55 2143030.380 0.953 3.395 117.68436 2.63 ug/L
r> In 115 1283355.998 1.307 1283355.998 ug/L
I Sb 121 426202.587 0.962 0.332 51.54004 1.86 ug/L
L Sb 123 331909.008 0.688 0.259 52.30318 1.66 ug/L
r> Ho 165 1767965.648 0.521 1767965.648 ug/L
L Tl 205 1284073.024 3.191 0.726 46.93812 2.75 ug/L
QC Calculated Values
Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff
r Be 9 96.083
Sc-1 45 99.458
L Mn 55 63.876 '
n in 115 97.314
I Sb 121 102.921
L Sb 123 104.446
r> Ho 165 98.437
L Tl 205 93.866
Calibration
Analyte MassCurve Type Correlation Coefficient
r Be 9Linear Thru Zero 0.999992
|> Sc-1 45 Linear Thru Zero
L Mn 55Linear Thru Zero 0.999983
r> In 115Linear Thru Zero
I Sb 121 Linear Thru Zero 0.999998
L Sb 123Linear Thru Zero 1.000000
r> Ho 165 Linear Thru Zero
L Tl 205Linear Thru Zero 0.999977