VOC analysis results, sample AE12279, May 2002

Machine-extracted title · confidence 95%

Laboratory report for volatile organic compounds in sample AE12279 analyzed on May 23, 2002.

NYC-WTC_000083564–000083679

Folder label: “524 5/23/02 - 5/24/02

Page image
Scanned page image, NYC-WTC_000083566
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Data File : C:\HPCHEM\l\DATA\02MAY23\0523Bl.D Vial: 1 Acq On : 23 May 2002 8:55 am Operator: 201-wb Sample : lab blank 1 (voc di) Inst : GC/MS Ins Mise Multiplr: 1.00 MS Integration Params: GAS6.P Quant Time: May 28 8:37 2002 Quant Results FileHP051702.RES Quant Method : C:\HPCHEM\1\METHODS\HP051702.M (RTE Integrator) Title : VOCs BY EPA METHOD 524 Last Update : Thu May 23 10:09:12 2002 Response via : Initial Calibration DataAcq Meth : HP052102

Internal Standards R.T. Qlon Response Cone Units Dev(Min) 1) 1,4-DIFLUOROBENZENE 15.05 114 1452989 5.00 ug/L 0.02 24) CHLOROBENZENE-D5 21.71 117 1340397 5.00 ug/L 0.00 52) 1,4-DICHLOROBENZENE-D4 26.90 152 643598 5.00 ug/L 0.02 System Monitoring Compounds 2) 1,2-DICHLOROETHANE-D4 14.28 65 705866 4.97 ug/L 0.02 Spiked Amount 5.000 Recovery = 99.40% 3) 4-BROMOFLUOROBENZENE 24.30 174 553785 5.40 ug/L 0.00 Spiked Tkmount 5.000 Recovery = 108.00% 25) TOLUENE-D8 18.40 98- 1767709 4.83 ug/L 0.00 Spiked Amount 5.000 Recovery = 96.60% Target Compounds Qvalue 12) ACETONE 8.22 43 12847 1.00 ug/L 95 14) METHYLENE CHLORIDE 9.55 49 7717 0.08 ug/L 94

(#) = qualifier out of range (m) = manual integration 0523B1.D HP051702.M Tue May 28 08:37:43 2002 Page 1

NYC-WTC_000083566

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000083566Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →