VOC analysis results, DEP Labs, May 2002

Machine-extracted title · confidence 95%

Laboratory report for volatile organic compounds in sample AE11409 analyzed on May 16, 2002.

NYC-WTC_000083264–000083272

Folder label: “524 5/11/02

Page image
Scanned page image, NYC-WTC_000083265
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (Not Reviewed) Data File C:\MSDCHEM\l\5973N\02MAY16\11410F.D Vial: 16 Acq On 17 May 2002 4:01 am Operator: Sample nyc; 'f b Inst ; Instrumen Mise Multiplr: 1.00 MS Integration Params: Lscint.p Quant Time: May 17 04:43:06 2002 Quant Results File: W042302.RES Quant Method : C:\MSDCHEM\1...\W042302.M (RTE Integrator) Title : VOC method 8260 Last Update : Wed May 01 09:30:08 2002 Response via : Initial Calibration DataAcq Meth : W042302

Internal Standards R.T. Qlon Response Cone Units Dev(Min) 1) 1,4-Difluorobenzene 17.69 114 849 5.00 ug/L 0.00 27) Chlorobenzene-d5 25.47 117 1521 5.00 ug/L 0.00 51) 1,4-Dichlorobenzene-d4 31.56 150 1504 5.00 ug/L 0.02 System Monitoring Compounds 2) 1,2-Dichloroethane-d4 16.76 65 397 12.85 ug/L 0.00 Spiked Amount 5.000 Recovery = 257.00% 17) Toluene-d8 21.62 98 1825 8.01 ug/L 0.00 Spiked Amount 5.000 Recovery = 160.20% 54) 4-Bromofluorobenzene 28.51 95 826 4.81 ug/L 0.00 Spiked Amount 5.000 Recovery 96.20% Target Compounds Qvalue 4) Chloromethane 6.19 50 1834 49.80 ug/L 79 11) Acetone 9.39 43- 130676 55850.78 ug/L. 98 13) Methylene Chloride 11.04 49 9188 308.24 ug/L 98 58) 1,3,5-Trimethylbenzene 29.23 105 1118 3.48 ug/L 71

(#) = qualifier out of range (m) = manual integration li410F.D W050302.M Fri May 24 15:09:32 2002 Page 1

NYC-WTC_000083265

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000083265Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →