Pesticide analysis results, sample AD23948, Oct 2001

Machine-extracted title · confidence 100%

Analytical results report for sample AD23948 listing pesticide compounds and concentrations with method detection limit qualifiers.

NYC-WTC_000081460–000081466

Folder label: “508 Xtract 10/4/01 Anal 10/31/01

Page image
Scanned page image, NYC-WTC_000081465
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed) Signal #1 C:\HPCHEM\1\DATA\5O8F\O11O3OB\23948.D\ECD1A.CH Vial: 48 Signal #2 C:\HPCHEM\1\DATA\5O8F\O11O3OB\23948.D\ECD2B.CH Acq On 1 Nov 2001 5:57 am Operator; Nefliu Sample sample Inst : 104 Mise : Multiplr: 1.00 IntFile Signal #1: events.e IntFile Signal #2: events2.e Quant Time: Nov 8 14:15 2001 Quant Results File; PCB1221.RES

Quant Method C;\HPCHEM\1\METHODS\PCB1221.M (Chemstation Integrator) Title DUAL 508 CHLORINATED PESTICIDES CHLORDANE 6/3/99 Last Update Thu Nov 08 14:09:09 2001 Response via Initial Calibration DataAcq Meth 508F2.M Volume Inj. : Signal #1 Phase : Signal #2 Phase: Signal #1 Info : Signal #2 Info : Compound RT#1 RT#2 Resp#l Resp#2 ug/L ug/L

System Monitoring Compounds 6) s 2,4-DDD SURROGAT 36.99 34.11 844138 982867 0.203 7.864 # Spilted Amount 0.100 Recovery = 203.00% 7864.00% Target Compounds 1) PEAK 1 12.58 13.16 6951 1346 0.072 0.045 # 2) PEAK 2 17.63 14.16 3019 12531 0.022 0.109 # 3) PEAK 3 18.81 15.43 1634 2943 0.017 0.038 # 4) PEAK 4 0.00 15.99f 0 8909 N.D. d 0.029 5) PEAK 5 20.18f 18.41 31531 32205 0.825 0.794

(f)=RT Delta > 1/2 Window (#)=Amounts differ by > 25% (m)=manual int. 23948.D PCB1221.M Thu Nov 08 14:15:56 2001 Page 1

NYC-WTC_000081465

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000081465Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →