Laboratory report listing quantitative results for chlorinated pesticides in sample AD23325.

NYC-WTC_000080366–000080388

Folder label: “508 9/26/01 Extract

Page image
Scanned page image, NYC-WTC_000080384
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed) Signal #1 - C:\HPCHEM\1\DATA\508F\011004\TOXC3.D\ECD1A.CH Vial: 20 Signal #2 C:\HPCHEM\1\DATA\508F\011004\TOXC3.D\ECD2B.CH Acq On 4 Oct 2001 11:13 pm Operator: Nefliu Sample tox ic3 Inst : 104 Mise : Multiplr: 1.00 IntFile Signal #1: events.e IntFile Signal #2: events2.e Quant Time: Oct 11 12:48 2001 Quant Results File: 011004T.RES

Quant Method : C:\HPCHEM\1\METHODS\011004T.M (Chemstation Integrator) Title : 508 CHLORINATED PESTICIDES TOXAPHENE7/28/99 Last Update : Fri Sep 28 15:07:47 2001 Response via : Initial Calibration DataAcq Meth : 508F.M

Volume Inj. Signal #1 Phase Signal #2 Phase: Signal #1 Info Signal #2 Info : Compound RT#1 RT#2 Resp#l Resp#2 ug/1 ug/1

System Monitoring Compounds 6) S 2,4-DDD SURROGAT 0.00 0.00 0 0 N.D. d N.D. d Spilced Amount 0.100 Recovery 0.00% 0.00% Target Compounds 1) TOXAPHENE PEAK 1 35.84 35.89 224371 231528 5.809 6.718m 2) TOXAPHENE PEAK 2 39.98 37.46 457360 718351 6.098m 6.659 3) TOXAPHENE PEAK 3 41.68 39.56 621105 508813 6.290m 6.896 4) TOXAPHENE PEAK 4 47.57 40.75 1488499 646586 7.156 7.894 5) TOXAPHENE PEAK 5 46.96 41.87 1079876 530850 6.622m 8.043

(f)=RT Delta > 1/2 Window (#)=Amounts differ by > 25% (m)=manual int. TOXC3.D 011004T.M Thu Oct 11 12:48:47 2001 Page 1

NYC-WTC_000080384

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000080384Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →