NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.7
← Document results/DEP Box 63/5 March 13, 2002 NEWQ AE03914 - AE04844
Document / 174 pages

Method 200.8 Water Analysis Summary Report, Mar 13, 2002

Machine-extracted title · confidence 95%

Summary of water sample results for metals analysis using Method 200.8 conducted on March 13, 2002.

NYC-WTC_000077030–000077203

Folder label: “5 March 13, 2002 NEWQ AE03914 - AE04844”

Page image
Scanned page image, NYC-WTC_000077143
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I Cu 63 97.093 L Cu 65 97.188 r Zn 66 102.863 I Zn 67 98.438 I Zn 68 102.223 i> Ge 72 96.716 As 75 102.571 I Se 77 110.194 L Se 82 109.830 Y 89 r Ag 107 91.469 i>In 115 98.984 I Sb 121 100.526 L Sb 123 101.108 r Ba Ba 135 137 94.722 I 95.244 i> Ho 165 100.298 I TI 205 96.326 L Pb 208 95.911 Calibration Analyte MassCurve Type Correlation Coefficient r Be 9Linear Thru Zero 0.999996 i> Sc-1 45Llnear Thru Zero 1 Cr 52Linear Thru Zero 0.999999 Cr 53Llnear Thru Zero 0.999989 1 Mn 55Llnear Thru Zero 0.999989 1 Nl 60Llnear Thru Zero 0.999997 I Cu 63Llnear Thru Zero 0.999991 L Cu 65Linear Thru Zero 0.999987 r Zn 66Llnear Thru Zero 0.999885 I Zn 67Llnear Thru Zero 0.999950 1 Zn 68Linear Thru Zero 0.999784 i> Ge 72Llnear Thru Zero I As 75Llnear Thru Zero 1.000000 I Se 77Linear Thru Zero 0.999992 L Se 82Linear Thru Zero 0.999999 Y 89Linear Thru Zero r AgIn 107Llnear Thru Zero 0.999975 i> 115Linear Thru Zero Sb 121 Linear Thru Zero 0.999999 L Sb 123Linear Thru Zero 0.999996 r Ba 135Llnear Thru Zero 0.999997 I Ba 137Llnear Thru Zero 0.999992 i> Ho 165L}near Thru Zero TI 205Linear Thru Zero 0.999957 L Pb 208Llnear Thru Zero 0.999953

Sample ID: AE04418 Report Date/Time: Wednesday, March 13, 2002 14:09:41 Page 2

NYC-WTC_000077143

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000077143Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →