NYC-WTC_000076883
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Summary of water sample results for metals analysis using Method 200.8 conducted on March 12, 2002.
NYC-WTC_000076981–000077028Folder label: “4 March 12, 2002 NEWQ AE03823 - AE03834”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: AE03824 Sample Date/Time: Tuesday, March 12,2002 12:29:30 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\NEWQ\NEWQ\AE03824.073 Aliquot Volume (ml): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 7.333 15.746 0.000 0.00258 73.79 ug/L |> Sc-1 45 469849.299 2.271 469849.299 ug/L I Cr 52 6899.361 6.719 0.002 0.13753 33.64 ug/L 1 Cr 53 776.041 4.178 0.001 0.50670 10.76 ug/L 1 Mn 55 256516.964 1.311 0.544 20.34738 3.58 ug/L Ni 60 1046.737 3.587 0.002 0.40837 6.63 ug/L 1 Cu 63 31260.971 0.755 0.062 6.87778 1.87 ug/L L Cu 65 15166.126 1.061 0.030 6.80200 3.36 ug/L r Zn Zn 66 67 2649.079 536.688 3.311 3.438 -0.029 -1.54009 4.12 ug/L -0.002 -0.70890 9.45 ug/L Zn 68 2307.316 0.217 -0.014 -1.05357 1.51 ug/L l> Ge 72 77061.006 0.506 77061.006 ug/L I As 75 666.010 9.473 0.009 0.44143 9.03 ug/L I Se 77 122.669 6.539 0.001 0.31092 20.19 ug/L L Se 82 110.668 2.905 0.000 0.20609 9.96 ug/L Y 89 980500.207 0.917 -61747.935 ug/L r Ag 107 385.679 18.984 0.000 0.00376 234.93 ug/L l> In 115 1026782.587 0.883 1026782.587 ug/L 1 Sb 121 791.042 8.458 0.001 0.11230 8.59 ug/L L Sb 123 634.272 15.529 0.001 0.11565 15.91 ug/L r Ba 135 33395.566 1.137 0.021 15.32607 1.05 ug/L 1 Ba 137 58955.145 0.943 0.038 15.46055 1.27 ug/L I: Ho 165 1543891.566 0.324 1543891.566 ug/L I Ti 205 354.344 10.417 0.000 0.00796 21.02 ug/L L Pb 208 5862.798 0.743 0.001 0.02703 4.40 ug/L
QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 |> Sc-1 45 93.753 I Cr 52 I Cr 53 I Mn 55 I Ni 60
Sample ID: AE03824 Report Date/Time: Tuesday, March 12, 2002 12:31:05 Page 1
NYC-WTC_000077005
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000076883
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076932
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077030
Summary of water sample results for metals analysis using Method 200.8 conducted on March 13, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076743
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076489
Summary of water sample results for metals analysis using Method 200.8 conducted on February 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076632
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076577
Summary of water sample results for metals analysis using Method 200.8 conducted on February 8, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078316
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 8, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078234
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076540
Summary of water sample results for metals analysis using Method 200.8 conducted on February 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077621
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated March 25, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078102
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000076980
Administrative record from the Department of Environmental Protection regarding World Trade Center activities on March 12, 2002.
Filed in the same folder
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 13, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
Similar indexed content