NYC-WTC_000076981
Summary of water sample results for metals analysis using Method 200.8 conducted on March 12, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
NYC-WTC_000076932–000076979Folder label: “3 March 11, 2002 NEWQ AE03616 - AE03822”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: AE03736 Sample Date/Time: Monday, March 11, 2002 14:45:39 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: D:\Elandata\Method\NEWQ200.8.mth Dataset File: d:\eiandata\Dataset\NEWQ\NEWQ\ AE03736.045 Aliquot Volume (ml): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 5.000 40.000 0.000 0.00216 173.85 ug/L i> Se-I 45 475549.378 0.109 475549.378 ug/L Cr 52 6697.534 1.698 -0.011 -0.68591 2.07 ug/L 1 Cr 53 1115.413 1.723 0.001 0.71508 3.12 ug/L 1 Mn 55 187081.304 0.847 0.392 14.69135 0.95 ug/L 1 Ni 60 966.728 6.254 0.002 0.39511 7.87 ug/L I Cu 63 41831.465 1.992 0.084 9.32677 2.16 ug/L L Cu 65 20394.722 0.551 0.041 9.48441 0.69 ug/L r Zn 66 5983.695 1.325 0.015 0.76596 9.44 ug/L I Zn 67 1062.739 2.333 0.004 1.20486 6.76 ug/L 1 Zn 68 4565.525 0.878 0.015 1.13883 4.25 ug/L i> Ge 72 75414.940 0.552 75414.940 ug/L 1 As 75 585.913 13.901 0.008 0.39658 13.30 ug/L I . Se 77 138.669 7.115 0.001 0.45382 17.40 ug/L L Se 82 91.668 2.745 0.000 0.19013 8.17 ug/L Y 89 967317.343 0.719 3694.316 ug/L r Ag 107 69.668 15.348 -0.000 -0.01383 9.17 ug/L i> In 115 1007828.836 0.513 1007828.836 ug/L Sb 121 384.012 3.003 0.000 0.05317 2.88 ug/L L Sb 123 292.171 3.427 0.000 0.05281 3.90 ug/L r Ba 135 29633.853 1.084 0.020 13.94718 0.81 ug/L 1 Ba 137 50807.430 0.948 0.034 13.78383 1.93 ug/L 1> Ho 165 1466779.431 0.999 1466779.431 ug/L I Tl 205 195.004 1.357 0.000 0.00303 7.26 ug/L L Pb 208 8739.739 0.625 0.003 0.15394 0.91 ug/L
QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 i> Se-I 45 96.197 Cr 52 I Cr 53 Mn 55 Ni 60
Sample ID: AE03736 Report Date/Time: Monday, March 11, 2002 14:47:14 Page 1
NYC-WTC_000076970
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000076981
Summary of water sample results for metals analysis using Method 200.8 conducted on March 12, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076883
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077030
Summary of water sample results for metals analysis using Method 200.8 conducted on March 13, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076743
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076577
Summary of water sample results for metals analysis using Method 200.8 conducted on February 8, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076632
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076489
Summary of water sample results for metals analysis using Method 200.8 conducted on February 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078316
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 8, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078234
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076540
Summary of water sample results for metals analysis using Method 200.8 conducted on February 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077621
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated March 25, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077705
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated March 28, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000076931
Administrative record from the Department of Environmental Protection regarding World Trade Center activities on March 11, 2002.
Filed in the same folder
Summary of water sample results for metals analysis using Method 200.8 conducted on March 12, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on March 13, 2002.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
Similar indexed content