NYC-WTC_000076227
Summary of water sample results for metals analysis using Method 200.8 conducted on January 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
NYC-WTC_000076306–000076437Folder label: “NEWQ Feb 1st, 2002 AE01966 - AE02567”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: LRB Sample Date/Time: Friday, February 01, 2002 09:50:07 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\LRB.111 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas, intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 13.667 30.463 -0.000 -0.01000 71.37 ug/L )> Sc-1 45 761112.273 3.748 761112.273 ug/L I Cr 52 9832.414 1.867 -0.000 -0.00293 1379.46 ug/L I Cr 53 604.360 6.795 -0.000 -0.01394 275.82 ug/L I Mn 55 1011.733 5.442 0.000 0.00329 99.41 ug/L 1 Ni 60 1773.191 4.090 -0.000 -0.01317 264.19 ug/L Cu 63 1615.493 1.151 -0.000 -0.00157 422.78 ug/L L Cu 65 806.711 3.525 0.000 0.00292 496.70 ug/L r Zn 66 3799.499 2.546 -0.000 -0.02086 113.67 ug/L I Zn 67 625.028 3.910 -0.000 -0.04962 130.19 ug/L I Zn 68 2697.094 0.841 -0.001 -0.05276 51.53 ug/L I > Ge 72 133808.648 1.157 133808.648 ug/L I As 75 7446.985 6.967 0.003 0.16632 141.43 ug/L L Se 77 151.669 7.585 -0.000 -0.05056 94.50 ug/L r Ag 107 1227.763 13.116 -0.000 -0.00578 158.58 ug/L |> In 115 1646661.095 2.957 1646661.095 ug/L Sb 121 194.337 17.976 -0.000 -0.00385 93.92 ug/L L Sb 123 145.216 9.592 -0.000 -0.00661 31.53 ug/L r Ba 135 268.007 7.283 -0.000 -0.00219 230.90 ug/L I Ba 137 451.682 4.572 -0.000 -0.00021 1122.06 ug/L |> Ho 165 2438049.585 3.516 2438049.585 ug/L I Tl 205 1435.129 14.719 0.000 0.00189 278.11 ug/L L Pb 208 5610.402 9.291 0.000 0.00046 2062.53 ug/L
QC Calculated Values Analyte Mass QC Std % Recovery int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 1> Sc-1 45 98.591 Cr 52 Cr 53 Mn 55 Ni 60 Cu 63 L Cu 65 r Zn 66 I Zn 67
Sample ID: LRB Report Date/Time; Friday, February 01,2002 09:51:38 Page 1
NYC-WTC_000076322
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000076227
Summary of water sample results for metals analysis using Method 200.8 conducted on January 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076077
Summary of water sample results for metals analysis using Method 200.8 conducted on January 24, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078102
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078151
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076743
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077814
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 2, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076632
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078234
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085904
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, and Nickel.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085726
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Selenium, Chromium, Manganese, and Nickel.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085207
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085187
Administrative record referencing NEWQ batch numbers 30010 through 30086 associated with January 3, 2002 testing.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
Cited alongside this record in an Ask answer
NYC-WTC_000054886
Westchester County Department of Labs and Research report detailing elemental analysis results for sample ID [name] using ICPMS Method 200.8.
Cited alongside this record in an Ask answer
Summary of water sample results for metals analysis using Method 200.8 conducted on February 6, 2002.
Cited alongside this record in an Ask answer
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
Cited alongside this record in an Ask answer
NYC-WTC_000127019
Label sheet identifying records associated with 156 Chambers Street in the WTC archive.
Cited alongside this record in an Ask answer