Summary of water sample results for metals analysis using Method 200.8 conducted on January 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
NYC-WTC_000076306–000076437Folder label: “NEWQ Feb 1st, 2002 AE01966 - AE02567”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: CCV STD2 60 PPB Sample Date/Time: Friday, February 01, 2002 15:28:02 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performance\CCV STD2 60 PPB. 167 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results /Xnalyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 35492.554 3.311 0.051 61.94551 4.90 ug/L |> Sc-1 45 691288.789 1.550 691288.789 ug/L I Cr 52 724160.347 2.461 1.035 58.32692 4.06 ug/L I Cr 53 84967.777 1.208 0.122 58.81717 1.75 ug/L Mn 55 1176449.329 1.861 1.701 60.27808 0.37 ug/L Ni 60 183291.761 3.676 0.263 56.91100 5.32 ug/L I Cu 63 429719.227 2.043 0.619 59.35307 0.50 ug/L L Cu 65 207946.076 2.022 0.300 58.30583 3.57 ug/L r Zn 66 139630.209 0.475 1.134 62.62249 1.65 ug/L I Zn 67 24067.725 0.634 0.196 61.16478 1.47 ug/L i. Zn 68 100027.822 2.347 0.813 61.02595 4.37 ug/L I> Ge 72 120067.403 1.910 120067.403 ug/L I As 75 142032.058 2.983 1.131 60.30227 4.82 ug/L L Se 77 12307.116 1.628 0.101 62.02035 ' 1.49 ug/L r Ag 107 931793.794 1.851 0.621 60.02743 5.01 ug/L I> In 115 1499481.261 3.300 • 1499481.261 ug/L 1 Sb 121 549879.782 1.178 0.367 59.12023 2.50 ug/L L Sb 123 423746.090 0.489 0.283 59.38597 2.82 ug/L r Ba 135 169905.446 4.099 0.073 56.10570 1.91 ug/L I Ba 137 299845.756 1.890 0.130 57.35246 4.11 ug/L |> Ho 165 2313381.112 2.311 2313381.112 ug/L 1 Tl 205 2307851.917 1.659 0.998 64.00022 3.79 ug/L L Pb 208 3114655.958 2.702 1.345 64.66^ 4.45 ug/L
QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 i> Sc-1 45 89.547 Cr 52 Cr 53 Mn 55 Ni 60 Cu 63 L Cu 65
Sample ID: CCV STD2 60 PPB Report Date/Time: Friday, February 01,200215:29:34 Page 1
NYC-WTC_000076434
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000076227
Summary of water sample results for metals analysis using Method 200.8 conducted on January 29, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076077
Summary of water sample results for metals analysis using Method 200.8 conducted on January 24, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078102
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078151
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076743
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077814
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 2, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076632
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078234
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085904
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, and Nickel.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085726
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Selenium, Chromium, Manganese, and Nickel.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085207
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085187
Administrative record referencing NEWQ batch numbers 30010 through 30086 associated with January 3, 2002 testing.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
Cited alongside this record in an Ask answer
NYC-WTC_000054886
Westchester County Department of Labs and Research report detailing elemental analysis results for sample ID [name] using ICPMS Method 200.8.
Cited alongside this record in an Ask answer
Summary of water sample results for metals analysis using Method 200.8 conducted on February 6, 2002.
Cited alongside this record in an Ask answer
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
Cited alongside this record in an Ask answer
NYC-WTC_000127019
Label sheet identifying records associated with 156 Chambers Street in the WTC archive.
Cited alongside this record in an Ask answer