NYC-WTC_000076077
Summary of water sample results for metals analysis using Method 200.8 conducted on January 24, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Summary of water sample results for metals analysis using Method 200.8 conducted on January 29, 2002.
NYC-WTC_000076227–000076304Folder label: “NEWQ January 29, 2002 AE01796 - AE01965”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Method 200.8 - Summary Report Sample ID: CCVSTD1 30 PPB Sample Date/Time: Tuesday, January 29, 2002 16:07:26 Sample Type: Sample Sample Description: Number of Replicates: 3 Batch ID: Method File: d:\elandata\Method\NEWQ200.8.mth Dataset File: d:\elandata\Dataset\daily performanceXCCV STD1 30 PPB.039 Sample Prep Volume (mL): Initial Sample Quantity (mg): Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit r Be 9 18693.066 3.303 0.024 29.76745 6.06 ug/L i> Se-I 45 769740.601 2.662 769740.601 ug/L I Cr 52 419315.679 5.906 0.531 29.69181 6.66 ug/L I Cr 53 48048.490 2.064 0.062 29.48221 1.44 ug/L I Mn 55 648058.730 1.744 0.841 29.60596 3.42 ug/L Ni 60 100098.836 1.696 0.130 27.99125 4.43 ug/L I Cu 63 239547.522 1.988 0.309 29.05559 1.64 ug/L L Cu 65 116347.509 3.410 0.150 28.47660 6.19 ug/L r Zn 66 77255.785 2.539 0.549 30.11057 2.16 ug/L I Zn 67 13301.528 2.522 0.095 29.77557 3.59 ug/L I Zn 68 55945.850 0.802 0.398 30.04488 1.80 ug/L |> Ge 72 134236.527 0.920 134236.527 ug/L I As 75 77247.429 1.393 0.565 29.93666 2.34 ug/L I Se 77 6817.625 2.690 0.050 30.60265 2.40 ug/L L Se 82 9627.525 1.147 0.067 31.36713 0.67 ug/L r Ag 107 407017.995 0.173 0.244 29.57179 1.55 ug/L l> In 115 1664441.518 1.384 1664441.518 ug/L 1 Sb 121 301292.219 2.228 0.181 29.26648 1.17 ug/L L Sb 123 235727.367 1.812 0.142 29.81505 2.76 ug/L r Ba 135 94526.845 0.309 0.037 28.56611 3.63 ug/L I Ba 137 167740.626 2.404 0.065 29.07382 5.89 ug/L |> Ho 165 2540214.667 3.743 2540214.667 ug/L I Tl 205 1190817.934 4.666 0.469 29.68131 7.64 ug/L L Pb 208 1642865.787 1.034 0.641 30.9999^6^ 2.82 ug/L
QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rei. % Diff r Be 9 1> Sc-1 45 91.412 I Cr 52 I Cr 53 I Mn 55 1 Ni 60
Sample ID: CeV STD1 30PPB Report Date/Time: Tuesday, January 29, 2002 16:08:57 Page 1
NYC-WTC_000076301
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000076077
Summary of water sample results for metals analysis using Method 200.8 conducted on January 24, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076306
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076743
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076883
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076632
Summary of water sample results for metals analysis using Method 200.8 conducted on February 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076981
Summary of water sample results for metals analysis using Method 200.8 conducted on March 12, 2002.
1 shared topics · Same agency, volume and box · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076489
Summary of water sample results for metals analysis using Method 200.8 conducted on February 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000076932
Summary of water sample results for metals analysis using Method 200.8 conducted on March 11, 2002.
1 shared topics · Same agency, volume and box · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085904
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, and Nickel.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085726
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Selenium, Chromium, Manganese, and Nickel.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085207
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, Nickel, and Copper.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000085187
Administrative record referencing NEWQ batch numbers 30010 through 30086 associated with January 3, 2002 testing.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000076226
Department of Environmental Protection record from folder NEWQ dated January 29, 2002 regarding World Trade Center site activities.
Filed in the same folder
Summary of water sample results for metals analysis using Method 200.8 conducted on January 24, 2002.
Similar indexed content
NYC-WTC_000085904
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Scandium, Chromium, Manganese, and Nickel.
Similar indexed content
NYC-WTC_000085726
Method 200.8 laboratory summary report listing elemental concentrations including Beryllium, Selenium, Chromium, Manganese, and Nickel.
Similar indexed content
Summary of water sample results for metals analysis using Method 200.8 conducted on February 1, 2002.
Similar indexed content