Laboratory results for drinking water samples collected on October 22, 2001, including beryllium levels.

NYC-WTC_000072841–000072858

Folder label: “25947

Page image
Scanned page image, NYC-WTC_000072852
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

REPORT OF ANALYSIS Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York

Agency: NYCDEP Bureau Water Sample NYC DEP 465 Columbus Ave. 19 WEST LAKE DRIVE Valhalla, NY 10595 VALHALLA, N.Y. Sample DEL18 Attention; Steve Schindler ID of Source: Received KM Collection 10/22/2001 AT 9:00:00 Bottle c315,p9287,9281,9278,q9250,92 Submitted 10/22/2001 AT 1:18:00 Collected By: CURCIO Sample Type: POT_DW Comment: PWS No.: Source Code: 000 Type Descriptor: Sample chilled on arrival? : YES Report

Sample No. AD25948 Method Test Description Results Units MDL Analyzed on Validator bis(2-Ethylhexyl)phthalate 28 ug/L 0.60 11/1/2001 DLV Butachlor < MDL ug/L 0.40 11/1/2001 DLV EPTC < MDL ug/L 1.0 11/1/2001 DLV Hexachlorobenzene < MDL ug/L 0.10 11/1/2001 DLV Hexachlorocyclopentadiene < MDL ug/L 0.10 11/1/2001 DLV Metolachlor <MDL ug/L 0.75 11/1/2001 DLV Metribuzin < MDL ug/L 0.15 11/1/2001 DLV Molinate < MDL ug/L 0.90 11/1/2001 DLV Simazine <MDL ug/L 0.40 11/1/2001 DLV Terbacil < MDL ug/L 2.0 11/1/2001 DLV The recovery for 1 of the 3 Surrogate Standards in this sample is below its acceptance range. Recoveries for 3 of the 18 compounds in the MDL and LCS Standards are outside of their acceptance ranges. Recoveries for 4 of the 18 compounds in the Spiked Sample are outside of their acceptance ranges. The level of 28 ug/L for bis(2-Ethylhexyl)phthalate may be due to handling during collection or laboratory contamination. GCMS Scan For Unknowns Other unknown compounds ug/L 12/12/2001 DLV A scan of the extract prepared for the 508 analysis, from 35-550 amu using a mass spectrometer, does not reveal the presence of non-target compounds.

Approved Pam Dilsizian QA Officer Date Approved: 12/17/2001

Environmental Laboratories emailed Original 12/17/2001

NYS ELAP #10108 Page 6 of 6

NYC-WTC_000072852

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000072852Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →