NYC 9/11 Public Portal Document
REPORT OF ANALYSIS
Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York
Agency: New York City DEP DWQC Sample QUEENS
Distribution Laboratory
96-05 Horace Harding Ex.
Corona N.Y. 11368 Sample 44550
Dr. Ian Hurley ID of Source:
Received EP Collection 10/31/2001 AT 8;37;00
Bottle C9801 ,Q458,436,433,P475,525,5 Submitted 11/1/2001 AT 11:27:00
Collected By: KAUZI Sample Type: POT_DW
Comment: PWS No.: Source Code:
Type Descriptor:
Sample chilled on arrival? : YES
Report
Sample No. AD26832
Method Test Description Results Units MDL Analyzed on Validator
bis(2-Ethylhexyl)phthalate 0.64 ug/L 0.60 11/13/2001 DLV
Butachlor <MDL ug/L 0.40 11/13/2001 DLV
EPTC <MDL ug/L 1.0 11/13/2001 DLV
Hexachlorobenzene <MDL ug/L 0.10 11/13/2001 DLV
Hexachlorocyclopentadiene <MDL ug/L 0.10 11/13/2001 DLV
Metolachlor <MDL ug/L 0.75 11/13/2001 DLV
Metribuzin <MDL ug/L 0.15 11/13/2001 DLV
Molinate <MDL ug/L 0.90 11/13/2001 DLV
Simazine <MDL ug/L 0.40 11/13/2001 DLV
Terbacil <MDL ug/L 2.0 11/13/2001 DLV
The recoveries for 5 of the 18 compounds in the LCS Standard were outside of their acceptance ranges. The
recoveries for 3 of the 18 compounds in the Spiked Sample were outside of their acceptance ranges. The
breakdown for Endrin in the Breakdown Standard was 48%.
GCMS Scan For Unknowns
Other unknown compounds ug/L 12/10/2001 DLV
A scan of the extract prepared for the 508 analysis, from 35-550 amu using a mass spectrometer, does not reveal
the presence of non-target compounds, except for the presence of bis(2-Ethylhexyl)phthalate at an estimated level
Approved Pam Dilsizian QA Officer Date Approved: 1/4/2002
Environmental Laboratories emailed Original 1/4/2002
NYS ELAP# 10108 Page 7 of 7
NYC-WTC_000071138