NYC 9/11 Public Portal Document
REPORT OF ANALYSIS
Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York
Agency: NYCDEP Bureau Water Sample NYC DEP
465 Columbus Ave. 19 WESTLAKE DRIVE
Valhalla, NY 10595 VALHALLA, NY
Sample CATLEFF
Attention: Steve Schindler ID of Source:
Received EP Collection 11/22/2001 AT 6:25:00
Bottle C723,P855,661 ,Q565,600,K8998 Submitted 11/23/2001 AT
Collected By: SUTTON Sample Typo: POT_DW
Comment: PWS No.: Source Code: 000
Type Descriptor:
Sample chilled on arrival? : YES
Report
Sample No. AD28689
Method Test Description Results Units MDL Analyzed on VaUdator
524.2 SEC-butylbenzene <MDL ug/L 0.5 11/27/2001 SV
524.2 Styrene <MDL ug/L 0.5 11/27/2001 SV
524.2 TERT-butylbenzene <MDL ug/L 0.5 11/27/2001 SV
524.2 Tetrachloroethene <MDL ug/L 0.5 11/27/2001 SV
524.2 Toluene <MDL ug/L 0.5 11/27/2001 SV
524.2 trans-1,2-dichloroethene <MDL ug/L 0.5 11/27/2001 SV
524.2 trans-1,3-dichloropropene <MDL ug/L 0.5 11/27/2001 SV
524.2 Trichloroethene <MDL ug/L 0.5 11/27/2001 SV
524.2 Trichlorofluoromethane <MDL ug/L 0.5 11/27/2001 SV
524.2 Vinyl chloride <MDL ug/L 0.5 11/27/2001 SV
GCMS ScariFor Unk s
Other unknown compounds ug/L 12/7/2001 DLV
The GCMS scan, fi-om 35 to 550 amu, does not reveal the presence of unusual compounds.
The recovery for the Surrogate Standard in this sample was 84%. Recoveries for 9 of the 44 compounds in the LCS
Standard were outside of their acceptance ranges. The chromatogram reveals contamination which has been
identified to be from the TurboVap concentrator. The pH of this sample when received was less than 2.
Approved Pam Dilsizian QA Officer Date Approved: 1/2/2002
Environmental Laboratories emailed Original 1/2/2002
NY8 ELAP # 10108 Page 4 of 4
NYC-WTC_000070837