NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 61/27817, 8, 9, 27823, 27826, 27828, 27831
Document / 28 pages

Water analysis report, Silver, Aluminum, Arsenic, Nov 2001

Machine-extracted title · confidence 50%

Lab report for NYC DEP water samples collected November 14, 2001, testing for silver, aluminum, and arsenic.

NYC-WTC_000070577–000070604

Folder label: “27817, 8, 9, 27823, 27826, 27828, 27831

Page image
Scanned page image, NYC-WTC_000070592
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

REPORT OF ANALYSIS Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York

Agency: New York City DEP DWQC Sample BROOKLYN Distribution Laboratory 96-05 Horace Harding Ex. Corona N.Y. 11368 Sample 25050 Dr. Ian Hurley ID of Source: Received LK Collection 11/13/2001 AT 1:23:00 Bottle C0635,Q745,747,749,P856,491 ,8 Submitted 11/14/2001 AT Collected By: MOHAN Sample Type: POT DW Comment: PWS No.: Source Code: Type Descriptor: Sample chilled on arrival? : YES Report

Sample No. AD27823 Method Test Description Results Units MDL Analyzed on Validator Benzo(a)pyrene <I\/1DL ug/L 0.20 11/20/2001 DLV bis(2-Ethylhexyl)adipate <MDL ug/L 0.60 11/20/2001 DLV bis(2-Ethylhexyl)phthalate <MDL ug/L 0.60 11/20/2001 DLV Butachlor <MDL ug/L 0.40 11/20/2001 DLV EPTC <MDL ug/L 1.0 11/20/2001 DLV Hexachlorobenzene 0.11 ug/L 0.10 11/20/2001 DLV Hexachlorocyclopentadiene <MDL ug/L 0.10 11/20/2001 DLV Metolachlor <MDL ug/L 0.75 11/20/2001 DLV Metribuzin <MDL ug/L 0.15 11/20/2001 DLV Molinate <MDL ug/L 0.90 11/20/2001 DLV Simazine <MDL ug/L 0.40 11/20/2001 DLV Terbacil <MDL ug/L 2.0 11/20/2001 DLV The recoveries for 3 of the 18 compounds in the LCS Standard were outside of their acceptance ranges. The recoveries for 2 of the 18 compounds in the Spiked Sample were below their acceptance ranges. The breakdown for Endrin in the Breakdown Standard was 64%. This may be because the injection port is set at 280 degrees Celcius. An investigation will be performed to evaluate injection port parameters. GCMS Scan For Unknowns Other unknown compounds ug/L 1/3/2002 DLV A scan of the extract prepared for the 508 analysis, from 35-550 amu using a mass spectrometer, does not reveal the presence of non-target compounds.

Approved Pam Dilsizian QA Officer Date Approved: 2/4/2002

Environmental Laboratories emailed Original 2/4/2002

NYS ELAP #10108 Page 4 of 4

NYC-WTC_000070592

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000070592Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000026064 · Box DEP Box 19

Laboratory report detailing trihalomethane compound analysis of water samples collected from Hillview Reservoir on September 18, 2001.

Cited alongside this record in an Ask answer

NYC-WTC_000026359 · Box DEP Box 19

Laboratory report detailing metal analysis of water samples collected from Hillview Reservoir on September 21, 2001.

Cited alongside this record in an Ask answer

NYC-WTC_000160154 · Box DEP Box 42

Summary of a DEP representative's attendance at an LMDC meeting regarding post-9/11 resident needs and tenant issues.

Cited alongside this record in an Ask answer

Compare copies and versions →