NYC 9/11 Public Portal Document
Element: Pb Seq. No.: 25 AS Loc.: 10 Date: 10/15/2001
Sample ID: 24028
pL‘ dispensed: 15 from 36, 5 from 37, 10 from 38, 5 from 10
Repl SampleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak
# pg/L pg/L Signal TVrea Height Area Height Stored
1 67.31 16.83 0.110 0.115 0.097 0.038 0.029 13:42:16 No
Recovery is 86.3%
Element: Pb Seq. No.: 26 AS Loc.: 11 Date: 10/15/2001
San^le ID: 24030
pL dispensed: 10 from 36, 5 from 37, 20 from 11
Repl SampleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak
# pg/L pg/L Signal Area Height Area Height Stored
1 20.14 20.14 0.131 0.136 0.117 0.074 0.037 13:44:59 No
Sample beyond calibration range. It will be diluted and reanalyzed.
Element: Pb Seq. No.: 27 AS Loc.: 11 Date: 10/15/2001
Sample ID: 24030
pL dispensed: 25 from 36, 5 from 37, 5 from 11
Repl SampleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak
# pg/L pg/L Signal Area Height Area Height Stored
1 28.08 7.020 0.048 0.053 0.057 0.022 0.019 13:47:42 No
Element: Pb Seq. No.: 28 AS Loc.: 11 Date: 10/15/2001
Saii5>le ID: 24030
pL dispensed: 15 from 36, 5 from 37, 10 from 38, 5 from 11
Repl San^leConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak
# pg/L pg/L Signal Area Height Area Height Stored
1 62.42 15.61 0.102 0.107 0.110 0.040 0.036 13:50:29 No
Recovery is 85.8%
Element: Pb Seq. No.: 29 AS Loc.: 1 Date: 10/15/2001
Saitfde ID: QCS
pL dispensed: 10 from 36, 5 from 37, 20 from 1
Repl San?>leConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak
# pg/L pg/L Signal Area Height Area Height Stored
1 4.463 4.463 0.031 0.036 0.071 0.012 0.021 13:53:11 No
QC out of limits. QC will be repeated based on Retry setting.
Element: Pb Seq. No.: 30 AS Loc.: 1 Date: 10/15/2001
San5>le ID: QCS
pL dispensed: 10 from 36, 5 from 37, 20 from 1
Repl San^jleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak
# pg/L pg/L Signal Area Height Area Height Stored
1 5.096 5.096 0.035 0.040 0.081 0.014 0.024 13:55:47 No
QC value within specified limits.
Page 13
NYC-WTC_000064555
OCR can misread numbers and units. Confirm readings against the page image before using them.