NYC-WTC_000064436
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
NYC-WTC_000064418–000064435Folder label: “Pb”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
:^=; = = =: = =: = = = = : :=z========== = s= =========== = = ====
Element: Pb Seq. No.: 73 AS Loc.: 32 Date: 09/18/2001 Sair^jle ID: 22657 pLh dispensed: 12 from 36, 5 from 37, 24 from 32 fih dispensed: 12 from 36, 5 from 37, 24 from 32
Repl San^jleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak # gg/L Signal Area Height Area Height Stored 1
Q.. Element: Pb San^le ID: 22739 -0.5827
Seq. No.: 74 -0.008
AS Loc.: 33 0.007 0.018
Date: 09/18/2001 0.008 0.006 14:53:11 No
fih dispensed: 12 from 36, 5 from 37, 24 from 33 fih dispensed: 12 from 36, 5 from 37, 24 from 33
Repl San^leConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak # Mg/h . 'X gg/L Signal Area Height Area Height Stored 1 -0.3814 \ -0.3814 -0.005 0.010 0.022 0.002 0.008 14:57:30 No
Element: Pb Seq. No.: 75 AS Loc.: 34 Date: 09/18/2001 San5)le ID: 22740 fih dispensed: 12 from 36, 5 from 37, 24 from 34 fih dispensed: 12 from 36, 5 from 37, 24 from 34
Repl SampleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak # Hg/h Signal Area Height Area Height Stored 1 k-0.2598 X -0.2598 -0.003 0.012 0.025 0.003 0.006 15:01:47 No
Element: Pb Seq. No.: 76 AS Loc.: 35 Date: 09/18/2001 Sample ID: 22741 Uh dispensed: 12 from 36, 5 from 37, 24 from 35 /zL dispensed: 12 from 36, 5 from 37, 24 from 35
Repl SampleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak # Mg/h Signal Area Height Area Height Stored 1 ' -0.3003 -0.3003 -0.004 0.012 0.025 0.002 0.007 15:06:01 No
:s===ss=s= = s=s==s:====s==s=s= = = ====== ===
Element: Pb Seq. No.: 77 AS Loc.: 2 Date: 09/18/2001 Sample ID: IPC lih dispensed: 12 from 36, 5 from 37, 24 from 2 /zL dispensed: 12 from 36, 5 from 37, 24 from 2
Repl SampleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak --- ^g/L gg/L Signal Area Height Area Height Stored 1 X 5.406 5.406 0.094 0.109 0.197 0.030 0.056 15:10:12 No QC value/within specified limits.
sssssssssscsss: :s= ===;=======s=============== = ==== = ;
Element; Pb Seq. No.: 78 AS Loc.: 3 Date: 09/18/2001 Sample ID: CB /zL dispensed: 12 from 36, 5 from 37, 24 from 3 Uli dispensed: 12 from 36, 5 from 37, 24 from 3
Repl SampleConc StndConc BlnkCorr Peak Peak Bkgnd Bkgnd Time Peak # gg/L gg/L Signal Area Height Area Height Stored 1 -0.6452 -0.6452 -0.009 0.006 0.016 0.013 0.008 15:14:22 No
Page 22
NYC-WTC_000064435
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000064436
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064466
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
1 shared topics · Same agency, volume and box · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064515
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
1 shared topics · Same agency, volume and box · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064531
Laboratory documentation listing sample IDs and analytical parameters for potable water lead testing conducted in October 2001.
1 shared topics · Same agency, volume and box · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064457
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
1 shared topics · Same agency, volume and box · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064571
Laboratory report listing sample IDs and analysis dates for lead testing in potable water.
1 shared topics · Same agency, volume and box · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064501
Laboratory report listing sample IDs for lead analysis conducted on October 1, 2001, including remarks on quality control rejection.
1 shared topics · Same agency, volume and box · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064491
Laboratory report listing sample IDs and quality control checks for a second run of lead analysis.
1 shared topics · Same agency, volume and box · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064544
Laboratory documentation listing sample IDs and analytical parameters for non-potable water lead testing conducted in October 2001.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064856
Laboratory report listing sample IDs and quality control status for antimony analysis conducted on October 5, 2001.
1 shared topics · Same agency, volume and box · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064798
Laboratory report listing sample IDs and analysis dates for antimony testing conducted in late September 2001.
1 shared topics · Same agency, volume and box · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000084101
List of sample IDs and quality control samples analyzed during the batch processed on November 29, 2001.
1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000064482
Laboratory report listing sample IDs and quality control status for lead analysis conducted on October 1, 2001.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064436
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064436
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064482
Laboratory report listing sample IDs and quality control status for lead analysis conducted on October 1, 2001.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064571
Laboratory report listing sample IDs and analysis dates for lead testing in potable water.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000064482
Laboratory report listing sample IDs and quality control status for lead analysis conducted on October 1, 2001.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000064412
Single-page lead analysis laboratory record with minimal readable content from DEP Box 59.
Filed in the same folder
NYC-WTC_000064413
Document containing lead sample identification codes and processing dates from the New York City Department of Environmental Protection archive.
Filed in the same folder
NYC-WTC_000064415
Fragmented text listing lead sample identifiers and processing dates from the WTC environmental monitoring program.
Filed in the same folder
NYC-WTC_000064436
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
Filed in the same folder
NYC-WTC_000064457
Laboratory report listing sample IDs and quality control checks for lead analysis in potable water.
Filed in the same folder