Comments for Sample AD22485 - Analysis $525
Westchester Dept, of Labs & Research
User; Vinci, David L
Date: 10-04-2001 Time: 14:19:06
Benzo(a)pyrene is present in this sample at an estimated level of 0.15 ug/L.
Two additional unidentified polynuclear aromatic hydrocarbons with mass 252 may
also be present at trace levels too low to confirm their identification by this
method. Bis(2-Ethylhexyl)phthalate was present in the Laboratory Blank at 0.37
ug/L. The recovery for bis(2-Ethylhexyl)phthalate in the MDL Standard was above
its acceptance range. The recoveries for Terbacil in the LCS Standard and the
Spiked Sample were above their acceptance ranges. The Field Blank associated
with this sample will be analyzed to support the Benzo(a)pyrene finding. This
sample was submitted to our laboratory using NYCDEP bottles. A reinjection and
analysis of this sample on 9/29/01 (with an increase in the electron multiplier
voltage and recalibtation) yields Benzo(a)pyrene at an estimated level of 0.15
ug/L, as indicated by its retention time and mass 252. Some supporting mass
spectra are present. The Laboratory Blank analysis was clean. The Field Blank
analysis is reported under laboratory number AD23470. It was clean also for
method 525.2.