Comrr»ents for Sample AD23698 - Analysis $525
Wes Chester Dept, of Labs & Research
Use : Vinci, David L
Date : 11-04-2001 Time: 12:41:09
Recoveries for four of the eighteen compounds in the MDL Standard were outside
of their acceptance ranges. Recoveries for three of the eighteen compounds in
the LCS Standard were outside of their acceptance ranges. Recoveries for four
and three of the eighteen compounds in the Spiked Sample and the Spiked
Duplicate Sample respectively, were outside of their acceptance ranges. The
recovery for one of the three Surrogate Standards in this sample was above its
acceptance range. The level for bis(2-Ethylhexyl)phthalate in the Laboratory
Bl^ank was 0.87 ug/L.
z