NYC-WTC_000060789
GCMS calibration verification report for sample AE06580 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗GCMS calibration verification report for sample AE07173 showing response factors for organic compounds.
NYC-WTC_000060909–000060915Folder label: “GCMS X 3/27/02 A 4/18/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
/ Data File : C:\MSDCHEM\l\DATA\041802\C25A0418.D Vial: 3 Acq On : 18 Apr 2002 10:11 am Operator: Bohlk Sample : C25 Inst Instrumen Mise Multiplr: 1.00 MS Integration Params: BENZO.P Quant Time: Apr 18 10:55:39 2002 Quant Results File: 5080402BBC.RES
Quant Method : C:\MSDCHEM\l\5973N\5080402BBC.M (RTE Integrator) Title : Quantitation For Method 508gcscan Last Update : Tue Apr 16 18:27:45 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN
Compound R.T. Qlon Response Cone Unit Qvalue
46) Di-n-Octylphthalate 32.62 149 2854102 50.48 ug/L 99 47) Benzo (b) fluoranthene 33.09 252 1785265 50.99 ug/L 94 48) Benzo (k) fluoranthene 33.16. 252 2010429 ■ 50.65 ug/L 96 49) Benzo (a) pyrene 33.88 252 1744135 50.77 ug/L 93 50) Indeno (1,2,3-cd) pyrene 36.53 276 943315 52.32 ug/L 86 51) Dibenz (ajh) anthracene 36.65 278 975024 53.47 ug/L 88 52) Benzo (g,h,i) perylene 37.19 276 1072518 55.77 ug/L 82
(#) = qualifier out of range (m) = manual integration C25A0418.D 5080402BBC.M Thu Apr 18 10:59:59 2002 Paige 2
NYC-WTC_00006091 1
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000060789
GCMS calibration verification report for sample AE06580 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060120
Laboratory report documenting GCMS analysis of environmental sample AE06049 conducted on April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060340
Laboratory report showing GC/MS calibration verification for Method 508 compounds with measured values.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060999
Calibration data for gas chromatography mass spectrometry listing response factors for multiple organic analytes.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060576
DEP laboratory report of GCMS calibration analysis for sample AE06800 conducted on April 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061192
Reference standard analysis report for gas chromatography mass spectrometry quantifying recovery of target analytes.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061009
Reference standard analysis report for gas chromatography mass spectrometry quantifying recovery of target compounds.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060796
GCMS reference standard analysis report for sample AE06580 showing response factors and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060916
Laboratory report listing quantitative GCMS results for multiple organic compounds in sample AE07173.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060127
Laboratory report showing GCMS reference standard analysis for sample AE06049 conducted on April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061188
Calibration data from gas chromatography mass spectrometry listing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039773
Quantitative results for volatile organic compounds in sample AE06585 analyzed on April 15, 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000060894
Environmental Protection Department record from the World Trade Center site dated March 2002.
Filed in the same folder
NYC-WTC_000060895
Document page showing GCMS extraction parameters and solvent lot numbers for WTC samples.
Filed in the same folder
NYC-WTC_000060901
GCMS blank analysis report for sample AE07173 showing compounds below detection limits.
Filed in the same folder
NYC-WTC_000060916
Laboratory report listing quantitative GCMS results for multiple organic compounds in sample AE07173.
Filed in the same folder
NYC-WTC_000060924
Laboratory report listing GCMS analysis results for reference standards associated with sample AE07173 on April 25, 2002.
Filed in the same folder